Abstract
There are many methods to reinforce the cylindrical structure for light weight design like skin-stringer and semi-monocoque. Isogrid is one of the reinforced structures to improve buckling load. Isogrid has many advantages for complex load case, internal pressure and concentrated load.In this paper, compressive buckling test and non-linear FE analysis of the isogrid panel are described. Diameter of panel is 2.4m and thickness of plate is 11.43mm. The angle which the panel accomplish is about 70 degrees and, its height is about 660mm. Local buckling, global buckling and variation of stiffness after local buckling were observed during buckling test of the panel. MSC/MARC is used for non-linear FE analysis. When analysis, initial imperfection of panel which occurred during plastic forming is considered. The results of analysis for buckling mode and buckling load have good agreements with test.
압축하중을 받는 실린더형 구조물에 대한 보강방법으로는 스킨-스트링거, 격자보강 형상 등 여러 종류가 있다. 그 중 isogrid 형상은 정삼각형형태의 보강대가 반복되는 보강구조로서 여러 가지 조합하중 및 집중하중에 대한 대처능력이 우수한 보강구조이다.본 논문에서는 격자보강 구조 중 isogrid 구조에 대한 압축 좌굴시험 및 비선형 해석을 수행하였다. Isogrid 패널은 두께가 11.43 mm, 높이가 660 mm, 외경이 2.4 m이며 70도의 원호를 이루는 알루미늄합금 일체형 구조이다. 시편에 대한 압축 좌굴시험을 통하여 국부좌굴강도, 전체좌굴강도, 국부좌굴후의 거동 등을 확인하였다. 또한 MSC/MARC를 이용한 비선형 FEM 해석을 수행하여 구조시험 결과와 비교하였다. 해석 시에는 패널의 소성 가공 시 발생한 형상공차를 고려하였다. 시험결과와 해석결과는 좌굴하중 및 좌굴모드가 모두 비교적 일치하였다.