A Study on the Cavity Height of Muti-Story Double-Skin Facade for better Thermal Performance

열성능을 고려한 다층형 이중외피의 중공층 높이에 관한 연구

  • Published : 2005.06.30

Abstract

In this study, the thermal performance of multi-story double-skin facade(DSF) with variation of cavity height is evaluated to offer useful data in determining cavity height of multi-story DSF. For this, thermal criteria for multi-story DSF is adopted and a DSF model for evaluation of the thermal performance is established. Through the evaluation of CFD simulation, the recommended height of multi-story DSF is 5 stories or less to improve the thermal performance during the intermediate season.

Keywords

References

  1. 환경친화적 피사드 시스템의 에너지 성능평가 서울대학교
  2. 적정 열성능을 고려한 다층형 이중의피 개구부 계획 방법에 관한 연구 신선준
  3. 블라인드가 이중외피의 열적 특성에 미치는 영향에 관한 연구 최동희
  4. Double-Skin Facades Oesterle;Leib;Lutz;Heusler;Green, Peter(tr.);Lieb, Rolf-Dieter(ed.)
  5. the Design Process for the Doulbe-Skin Facade to Minimize Thermal Loads in Apartment Buildings Park, S.J.