작업복의 연소특성에 관한 실험적 연구

An Experimental Study on the Burning Characteristics of Working Uniform

  • 방창훈 (경북전문대학 소방안전관리과) ;
  • 이진호 (육군3사관학교 기계공학과) ;
  • 김병호 (경일대학교 기계공학부)
  • 발행 : 2005.03.01

초록

본 논문에서는 작업복의 연소특성을 실험적으로 연구하였으며, 초기 점화위치는 상의소매 부분, 상의전면 중앙부분 및 하의무릎 부분으로 하였다. 실험결과는 다음과 같다. 미연소 질량비는 점화위치가 하의무릎 부분의 경우가 가장 빨리 감소하며 다음으로 상의소매 부분, 상의전면 중앙부분의 경우 순으로 감소하였다. 최고평균표면온도는 점화위치가 상의소매 부분, 상의전면 중앙부분, 하의무릎 부분의 경우 순으로 높게 나타났다. 연소 중 최고복사열유속은 점화위치가 상의소매 부분$(0.5\;W/cm^2)$, 상의전면 중앙부분 $(0.45\;W/cm^2)$, 하의무릎 부분$(0.44\;W/cm^2)$의 경우 순으로 높게 나타났다.

Burning characteristics of working uniform was studied in this paper experimentally. Initial ignition point was classified in three cases that is midpoint of sleeve (Sleeve case), front side midpoint of coat (Center case) and midpoint of trousers (Leg case). The results are as follows· The remained mass ratio was decreased in order of Leg case, Sleeve case, Center case. And the highest average temperature of surface was appeared in order of Sleeve case, Center case, Leg case. Maximum radiant heat flux during burning was appeared high in order of Sleeve case $(0.5\;W/cm^2)$, Center case $(0.45\;W/cm^2)$, Leg case $(0.44\;W/cm^2)$.

키워드

참고문헌

  1. B.V. Holcombe and B.N. Hoschke, 'Do Test Methods Yield Meaningful Performance Specifications', Performance of Protective Clothing, ASTM STP 900, R. L. Baker and G. C. Coletta, Eds., American Society for Testing and Materials, Philadelphia, pp.327-339(1986)
  2. W. Parker, 'Calculations of the Heat Release Rate by Oxygen Consumption for Various Applications', NBSIR 81-2427, National Bureau of Standards, Gaithersburg, MD(March 1982)
  3. D.W. Stroup et al., 'Large Fire Research Facility Heat Release Rate Measurement System', NISTIR 6509, National Institute of Standards and Technology, Gaithersburg, MD(July 1982)
  4. D.W. Stroup, L. Delauter, J. Lee, and G. Roaddarmel, 'Fire Tests of Men's Suits on Racks', Report of Test FR 4013, National Institute of Standards and Technology, Gaithersburg, MD(December 2001)
  5. D.A. Torvi, 'Heat Transfer in Thin Fibrous Materials Under High Heat Flux Conditions', PhD thesis Mechanical Eng. Dept., University of Alberta, Calgary, Alberta(1997)
  6. J. Lawson, 'Fire Fighter's Protective Clothing and Thermal Environments of Structural Fire Fighting', NISTIR 5804, National Institute of Standards and Technology, Gaithersburg, MD, (August 1996)
  7. M, W.E, Lawson, J., 'A Heat Transfer Model for Fighter's Protective Clothing', NISTIR 6299, National Institute of Standards and Technology, Gaithersburg, MD, (January 1999)
  8. Yoo Hwa Sook, Ning Pan, and Gang Sun, 'Change of Physical and Mechanical Properties of Firefighter Protective Clothing after Radiant Heat Exposure', J. of the Korean Society of Clothing and Textiles, Vol. 23, No.6, pp.853-863(1999)
  9. 방창훈, 이진호, 예용택, '복사열에 노출된 작업복의 열적특성에 관한 실험적 연구', 산업안전학회 논문집 Vol. 17, No.3, pp.56-60(2002. 9)