Abstract

A real-time monitoring and modeling system (RTMMS) for rainfall-induced turbidity flow, which is one of the major obstacles for sustainable use of reservoir water resources, is under development. As a prediction model for the RTMMS, a laterally integrated two-dimensional hydrodynamic and water quality model, CE-QUAL-W2 was tested by simulating the temperature stratification, density flow regimes, and temporal and spatial distributions of turbidity in a reservoir. The inflow water temperature and turbidity measured every hour during the flood season of 2004 were used as the boundary conditions. The monitoring data showed that inflow water temperature drop by 5 to $10^{\circ}C$ during rainfall events in summer, and consequently resulted in the development of density flow regimes such as plunge flow and interflow in the reservoir. The model showed relatively satisfactory performance in replicating the water temperature profiles and turbidity distributions, although considerable discrepancies were partially detected between observed and simulated results. The model was either very efficient in computation as the CPU run time to simulate the whole flood season took only 4 minutes with a Pentium 4(CPU 2.0GHz) desktop computer, which is essentially requited for real-time modeling of turbidity plume.

저수지를 통한 수자윈의 지속적 확보와 이용에 걸림돌이 되고 있는 탁수의 장기발생문제를 기술적으로 해결하고자 실시간 탁수 감시와 예측시스템(RTMMS)을 구축 중이며, 2004년 홍수기 동안 대청호를 대상으로 유입하는 탁수의 수리 및 수질특성을 조사하고 2차원 횡방향 평균 수리 및 수질모형인 CE-QUAL-W2(W2)를 적용하여 탁수의 밀도류 거동과 시${\cdot}$공간적 분포를 예측하고 실측값과 비교하여 모형의 적용가능성을 평가하였다. 강우사상 동안 하천 수온은 $5{\sim}10^{\circ}C$ 정도 하강하였으며 탁수가 저수지내에서 밀도류를 형성하는 원인으로 작용했다. 적용된 W2모형은 수온의 성층구조 변화와 탁수의 침강점, 도달시간, 중층밀도류 두께 등 탁수의 거동특성을 비교적 잘 모의하였다. 그러나 국부적으로 탁수가 위치한 중층과 탁수 유입 전에 형성되었던 전이층에서 수온과 탁도의 모의값과 실측값이 유의할 만한 오차를 보였다. 펜티엄급 PC(CPU 2.0GHz)로 홍수기 전체기간 모의에 소요된 시간은 약 4분으로써 모형은 계산의 효율성 측면에서 실시간 모의에 적합한 것으로 평가된다.

Keywords

References

  1. 김윤희, 김범철, 최광순, 서동일 (2001). '2차원 수리수질모델을 이용한 소양호 수온성층현상과 홍수기 밀도류 이동 현상의 모델링.' 대한상하수도학회지, 15(1), pp.40-49
  2. 나은혜, 안규홍, 박석순 (2002). '팔당호의 계절적 전도현상과 연직 수온 분포에 관한 모델 연구.' 대한환경공학회지, 24(5), pp.901-910
  3. 박기영 (2003). 2차원 수치모형을 활용한 임하댐 탁도 분석 시스템 구축, 석사학위논문, 경북대학교
  4. 박옥란, 박석순 (2002). '옥정호의 연직 수온분포에 관한 시변화 모델 연구.' 한국육수학회지, 35(2), pp.79-91
  5. 이상욱, 서동일, 정세웅 (2003). '2차원 수리.수질모델(CE-QUAL-W2)을 이용한 대청호 수온 성층 현상의 모델링.' 2003 춘계학술연구발표회논문집, 대한환경공학회, pp.676-678
  6. 정세웅 (2002). '성층 저수지로 유입하는 탁류의 유동 특성과 영향에 관한 연구.' 2002년 한국농공학회 학술발표논문집, pp.269-272
  7. 정세웅 (2004). '성층화된 저수지로 유입하는 탁류의 공간분포 특성 및 연직 2차원 모델링.' 대한환경공학회지, 26(9), pp.970-978
  8. 정세웅, 박기영, 한건연, 박기영 (2004). '임하호 탁수거동 분석을 위한 CE-QUAL-W2 모형의 적용.' 2004 춘계학술발표회 논문집, 대한환경공학회, pp.1220-1225
  9. 한국수자원공사 (1991). 대청댐 퇴사량 측정 보고서
  10. 한국수자원공사 (2000). 댐 저수지 탁류 및 오염물질 이송.확산 모의기술 개발
  11. 한국수자원공사 (2004a). 임하댐 탁수저감 방안 수립 보고서
  12. 한국수자원공사(2004b). 대청댐 주변지역 환경정비 기본계획
  13. Alavian, V., Jirka, G. H., Denton, R. A., Johnson, M. C., and Stefan, H. G.(1992). 'Density currents entering lakes and reservoirs.' J. Hydr. Eng., 118(11), pp. 1464-1489 https://doi.org/10.1061/(ASCE)0733-9429(1992)118:11(1464)
  14. Ambrose, R. B. Jr., Wool, T.A., and Martin, J. L.(1993). WASPS a hydrodynamic and water quality model, user's manual and programmer's guide(Parts I), U.S. Environmental Protection Agency, Athens, GA
  15. Chung, S. W., and Gu, R., (1998). 'Two-dimensional simulations of contaminant currents in stratified reservoir.' J. Hydr. Eng., 124(7), pp.704-711 https://doi.org/10.1061/(ASCE)0733-9429(1998)124:7(704)
  16. Cole, T. M., and Wells, S. A.(2003). CE-QUAL-W2: A two-dimensional, laterally averaged, hydrodynamic and water quality model, Version 3.1 user's manual, Instruction Report EL-03-1, U.S. Army Engineers, Washington, DC
  17. Cole, T.M., and Buchak, E.M., (1995). CE-QUAL-W2: a two-dimensional, laterally averaged, hydrodynamic and water quality model, user's manual, U.S. Army Engineers Waterways Experiment Station, Vicksburg, MS
  18. Fischer, H. B., List, E. J., Koh, R. C. Y., Imberger, J., and Brooks, N. H., (1979). Mixing in inland and coastal waters, Academic Press, New York, NY
  19. Ford, D.E. and Johnson, L.S.(l981) 'Field observations of density currents in impoundments.' In Proceedings of Symposium on Surface Water Impoundments, Stefan, H. G.(Eds.), Am. Soc. of Civil Eng., NY
  20. Kennedy, R. H.,Thornton, K.W., and Gunkel, R.C. Jr.(1982). 'The establishment of water quality gradients in reservoirs.' J. of Can. Wat. Res., 7, pp. 71-87 https://doi.org/10.4296/cwrj0701071
  21. Neumann, D. W., Rajagopalan, B., and, Zagona, E. A., (2003). 'Regression Model for Daily Maximum Stream Temperature.' J. of Envir. Engr., pp.667-674 https://doi.org/10.1061/(ASCE)0733-9372(2003)129:7(667)

Cited by

  1. Evaluation of Suspended Solids and Eutrophication in Chungju Lake Using CE-QUAL-W2 vol.46, pp.11, 2013, https://doi.org/10.3741/JKWRA.2013.46.11.1115
  2. Parameter Sensitivity Analysis for Spatial and Temporal Temperature Simulation in the Hapcheon Dam Reservoir vol.46, pp.12, 2013, https://doi.org/10.3741/JKWRA.2013.46.12.1181
  3. Water Transportation and Stratification Modification in the Andong-Imha Linked Reservoirs System vol.30, pp.1, 2014, https://doi.org/10.15681/KSWE.2014.30.1.031
  4. Effect of Pollutants Control Measures in So-oak Watershed on the Control of Algae Growth in Daecheong Reservoir vol.25, pp.4, 2016, https://doi.org/10.14249/eia.2016.25.4.248
  5. Evaluation of Future Turbidity Water and Eutrophication in Chungju Lake by Climate Change Using CE-QUAL-W2 vol.47, pp.2, 2014, https://doi.org/10.3741/JKWRA.2014.47.2.145
  6. Projection of the Climate Change Effects on the Vertical Thermal Structure of Juam Reservoir vol.30, pp.5, 2014, https://doi.org/10.15681/KSWE.2014.30.5.491