Effects of anesthetics on resistive index of the medial long posterior ciliary artery and ophthalmic artery using color doppler imaging

  • Choi, Ho-jung (College of Veterinary Medicine, Chungnam National University) ;
  • Lee, Young-won (College of Veterinary Medicine, Chungnam National University) ;
  • Yoon, Jung-hee (College of Veterinary Medicine, Seoul National University) ;
  • Yeon, Seong-chan (College of Veterinary Medicine, Gyeongsang National University) ;
  • Lee, Hyo-jong (College of Veterinary Medicine, Gyeongsang National University) ;
  • Lee, Hee-chun (College of Veterinary Medicine, Gyeongsang National University)
  • 심사 : 2005.08.28
  • 발행 : 2005.09.22

초록

Color Doppler imaging (CDI) was carried out to evaluate the anesthetics effect on ophthalmic circulation using CDI-derived resistive index (RI) values. CDI was preformed on 24 dogs, and RI values were calculated for the medial long posterior ciliary artery (mLPCA) and ophthalmic artery (OA) before and after administration of anesthetics. After administration of benoxinate or acepromazine, a significant change of the mLPCA RI was not found. But, a significant decrease of the RI following ketamine (p < 0.001) or xylazine (p < 0.01) administration could be observed as compared with the self-control. Mean RI value of OA also showed this same trend. Intraocular pressure was significantly decrease following benoxinate (p < 0.01), acepromazine (p < 0.01), and xylazine (p < 0.001) administration within normal range. The results suggest that some anesthetics influence on ophthalmic vascular resistance. Therefore, chemical restraint was carefully used in clinical application of CDI-derived RI measurement. Particularly, benoxinate and acepromazine is useful chemical restraint without a change of the ophthalmic vascular resistance.

키워드

참고문헌

  1. Adamson SL, Morrow RJ, Langille BL. Sitedependent effects of increases in placental vascular resistance on the umbilical arterial velocity waveform in fetal sheep. Ultrasound Med Biol 1990, 16, 19-27 https://doi.org/10.1016/0301-5629(90)90082-N
  2. Alexandra W, Wilkie DA, Myer CW. Ultrasonographic abnormalities in the eyes of dogs with cataracts : 141cases (1986-1992). J Am Vet Med Assoc 1993, 203, 838-841
  3. Awschalom L, Meyers SM. Ultrasonography of vitreal foreign bodies in eyes obtained at autopsy. Arch Ophthalmol 1982, 100, 979-980 https://doi.org/10.1001/archopht.1982.01030030987018
  4. Baxter GM, Williamson TH. Color Doppler imaging of the eye : Normal ranges, reproducibility, and observer variation. J Ultrasound Med 1995, 14, 91-96
  5. Boroffka SA, Verbruggen AJ, Boeve MH, Stades FC. Ultrasonographic diagnosis of persistent hyperplastic tunica vasculosa lentis/persistent hyperplastic primary vitreous in two dogs. Vet Radiol Ultrasound 1998, 39, 440-444 https://doi.org/10.1111/j.1740-8261.1998.tb01632.x
  6. Coleman DJ, Lizzi FL. Computerized ultrasonic tissue characterization of ocular tumors. Am J Ophthalmol 1983, 96, 165-175 https://doi.org/10.1016/S0002-9394(14)77784-0
  7. Cottrill NB, Banks WJ, Pechman RD. Ultrasonographic and biometric evaluation of the eye and orbit of dogs. Am J Vet Res 1989, 50, 898-903
  8. Dziezyc J, Hager DA, Millichamp MJ. Two-dimensional real-time ocular ultrasonography in the diagnosis of ocular lesions in dogs. J Am Anim Hosp Assoc 1987, 23, 501-507
  9. Gelatt KJ, Gelatt KN, Mackay E, Brooks DE, Newell SM. Doppler imaging of the ophthalmic vasculature of the normal dog : Blood velocity measurements and reproducibility. Vet Ophthalmol 1999, 2, 87-96 https://doi.org/10.1046/j.1463-5224.1999.00062.x
  10. Giovagnorio F, Quaranta L, Bucci MG. Color Doppler assessment of normal ocular blood flow. J Ultrasound Med 1993, 12, 473-477 https://doi.org/10.7863/jum.1993.12.8.473
  11. Greenfield DS, Heggerick PA, Hedges TR. Color doppler imaging of normal orbital vasculature. Ophthalmology 1995, 102, 1598-1605 https://doi.org/10.1016/S0161-6420(95)30822-6
  12. Grunwald JE, Riva CE, Kozart DM. Retinal circulation during a spontaneous rise of intraocular pressure. Br J Ophthalmol 1988, 72, 754-758 https://doi.org/10.1136/bjo.72.10.754
  13. Heechun Lee, Dongwoo Chang, Youngwon Lee, Kidong Eom, Hojung Choi, Kangmoon Seo, Mincheol Choi, Junghee Yoon. Use of color Doppler imaging for determining the resistive index of the medial long posterior ciliary artery in clinically normal conscious dogs. Am J Vet Res 2002, 63, 211-214 https://doi.org/10.2460/ajvr.2002.63.211
  14. Homco LD, Ramires O. Ultrasonographic diagnosis retrobulbar abscesses. Vet Radiol Ultrasound 1995, 36, 240-242 https://doi.org/10.1111/j.1740-8261.1995.tb00253.x
  15. Lieb WE, Cohen SM, Merton DA, Shields JA, Mitchell DG, Goldberg BB. Color doppler imaging of the eye and orbit : Technique and normal vascular anatomy. Arch Ophthalmol 1991, 109, 527-53 https://doi.org/10.1001/archopht.1991.01080040095036
  16. Miller WW, Cartee RE. B-scan ultrasonography for the detection of space occupying ocular masses. J Am Vet Med Assoc 1985, 187, 66-68
  17. Paulsen ME, Lavach JD, Severin GA, Eichenbaum JD. The effect of lens-induced uveitis on the success of extracapsular cataract extraction : A retrospective study of 65 lens removals in the dog. J Am Anim Hosp Assoc 1986, 22, 49-56
  18. Riva CE, Sinclair SH, Grunwald JE. Autoregulation of retinal circulation in response to decrease of perfusion pressure. Invest Ophthalmol Vis Sci 1981, 21, 34-38
  19. Rubin LF, Koch SA. Ocular dianostic ultrasonography. J Am Vet Med Assoc 1968, 153, 1706-1717
  20. Schiffer SP, Rantanen NW, Leary GA, Bryan GM. Biometric study of the canine eye, using A-mode ultrasonography. Am J Vet Res 1982, 43, 826-830
  21. Schoster JV, Dubielzig RR, Sullivan L. Choroidal melanoma in a dog. J Am Vet Med Assoc 1993, 203, 89-91
  22. Slatter, D. Structure and function of the eye. In : Slatter, D. (ed) Fundamentals of Veterinary Ophthalmology. pp. 7-9, Saunders, Philadelphia, 1981
  23. Thompson RS, Trudinger BJ, Cook CM. Doppler ultrasound waveform indices; A/B ratio, pulsatility index and Pourcelot ratio. Br J Obstet Gynaecol 1988, 95, 581-588 https://doi.org/10.1111/j.1471-0528.1988.tb09487.x
  24. Williamson TH, Baxter GM, Dutton GN. Colour doppler velocimetry of the arterial vasculature of the optic nerve head and orbit. Eye 1993, 7, 74-79
  25. Yu D, Alder VA, Cringle SJ, Brown MJ. Choroidal blood flow measured in the dog eye in vivo and in vitro by local hydrogen clearance polarography : Validation of a technique and response to raised intraocular pressure. Exp Eye Res 1988, 46, 289-303 https://doi.org/10.1016/S0014-4835(88)80021-6