Abstract

In order to improve the reliability of high voltage rotating machines and mold transformers, it is necessary to understand the breakdown mechanism and life assessment of the high voltage winding parts. Especially the on-line PD test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting the electrical machines, this method has been proven the major testing technology. Capacitive couplers have been the most widely used sensors for the on-line partial discharge detection in rotating machines nowadays. This paper deals with the electrical characteristics and long-term reliability of a ceramic coupler(CC), which can be easily mounted into high voltage input terminal part, has been developed and tested to continuously measure PD activity during operating condition. This paper presents electrical characteristics (dielectric loss angle, capacitance, PD inception level, breakdown voltage, and frequency response bandwidth) and long-term life test result of the developed 6.6 kV class on-line ceramic coupling sensor. It was found that this sensor had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz. Also, the voltage life of the 6.6kV class ceramic coupler was calculated over 60 years.

Keywords

References

  1. 강동식 외 '고압 회전기 On-line 부분방전 측정용 Cermic Coupler 특성', 대한전기학회지, Vol. 51C, No. 5, pp. 205-212, 2002
  2. I.M. Culbert, H. Dhirani and G.C. Stone, 'Handbook to Assess the Insulation Condution of Large Rotating Machines (Volume 16)', EPRI publication EL-5036, 1989
  3. IEEE Std 1434-2000, 'IEEE Trial-Use Guide to the Measurement of Partial Discharges in Rotating Machinery', Aug. 2000
  4. Ken Kimura, Yoshiharu Kaneda,Koji Mio, Satoru Kuroki, Teruya Osawa and Hiroki Tanaka 'On-line Partial Discharge Monitor for Turbine Generator', Proceedings of the International Conference on Electrical Engineering 1999 (ICEE '99), Vol. 1, pp. 172-175, 1999
  5. Dong-Sik Kang, Jong-Ho Sun, Yong- Joo Kim, 'On-Line Partial Discharge Measuring Techniques of Mold Transforme', KJ 2003
  6. IEEE Std 275-1992, 'IEEE Recommended Practice for Thermal Evaluation of Insulation Systems for Alternating-Current Electric Machinery Employing Form-Wound Pre-insulated Stator Coils for Machines Rated 6900V and Below'
  7. IEC 60034-18-31-1996, 'Test procedure for formwound windings -Thermal evaluation and classification of insulation systems used in machines up tp and including 50 MVA and 15kV'
  8. T. W. Dakin et al, 'The Voltage Endurance of Cast Resin', Proc. IEEE International Conference on Electrical Insulation, No. 216. 1973. 06
  9. 井關 他, '絶緣の劣 電壓劣化に關す考察', 電氣學會全國大會, No.277, 1982
  10. 電氣學會, 絶緣ッステム複合要因劣化に關する硏究の現狀', 電氣學會技術報告(II部) 第225호,1986
  11. H. Zhu, V. Green, M. Sasic and S. Halliburton, 'Increased Sensitivity of Capacitive Couplers for In-Service PD Measurement in Rotating Machines', IEEE Transactions on Energy Conversion, Vol. 14, No.4, December 1999 https://doi.org/10.1109/60.815045
  12. ANCI C29.l1, 'Composite Suspension Insulators for Overhead Transmission Lines-Tests', 1996
  13. EIAlIS-692, 'Ceramic Capacitor Qualification Specification', 1996