Abstract

The optimal seismic retrofitting of NPP(Nuclear Power Plant) cabinet structures that contain seismic category 1 relays was studied in this paper. During earthquake event, the failure modes of relays are not appeared in form of structural failure, but are appeared in form of contact chatter of relay. Therefore, the retrofitting of cabinet has to be aimed at the reducing of the structural response, such as acceleration. In this study, the optimal characteristic values of dampers were searched by ${\mu}$-GA (micro-Genetic Algorithm) scheme for several installation patterns. To keep accuracy and efficiency of analysis, the structural models of cabinet were considered as a frame structure. The responses of structure were obtained inform of acceleration response spectra derived from the results of nonlinear time history analysis including damping nonlinearity. The objective function of the optimum procedure was constructed based on the maximum ratio of maximum spectral value and target GERS (General Equipment Ruggedness Spectra). The results show the good improvements of fitness for adequate retrofitting pattern. Especially, the improvements of fitness were remarkable when the values of damping exponents are low.

본 논문에서는 원전내부의 내진범주 1급 계전기를 포함하고 있는 캐비닛 구조물의 최적내진보강에 대한 연구를 수행하였다. 지진시 계전기는 구조적인 파괴보다는 떨림에 의한 기능적 파괴가 발생한다. 이를 방지하기 위해서는 캐비닛구조물의 응답을 적정 수준이하로 감소시켜야 하므로 다양한 감쇠보강의 설치패턴에 따라 최적의 감쇠계수를 ${\mu}$-GA(micro-Genetic Algorithm)기법을 이용하여 산정하였다. 대상캐비닛 구조물은 해석의 정확도와 계산의 효율성을 만족시키기 위해 이용한 프레임구조로 모델링되었다. 구조물의 응답은 감쇠기의 비선형거동을 고려한 비선형 시간이력해석에 의해 얻어진 가속도응답스펙트럼으로 나타내었다. 목적함수는 구조물의 해석에서 얻어진 응답스펙트럼의 최대값과 목표 포괄기기내진력 스펙트럼 (GERS; General Equipment Ruggedness Spectra)의 최대응답비를 기초로 작성되었다. 해석결과 적절한 보강패턴을 선정한 경우 좋은 적합도의 향상을 보였으며 특히 감쇠지수의 값이 작은 경우 적합도의 개선효과가 뛰어났다.

Keywords

References

  1. GL 87-02, 'Verification of Seismic Adequacy of Mechanical and Electrical Equipment in Operating Reactors, Unresolved Safety Issue (USI) A-46,' USNRC, 1987
  2. Seismic Qualification Utility Group, Generic Implementation Procedure(GIP) for Seismic Verification of Nuclear Power Plants Equipment, Revision 2A, Corrected 2/ 14/92, 1993. 2
  3. 이계희, 김재민, 김상윤, '원자력 발전소 캐비닛구조물의 내진보강', 한국지진공학회 논문집, 제 7권 4호, 2003, pp. 31-37
  4. E. Vonk, L. C. Jain and R. P. Johnson, Automatic generation of neural network architecture using evolutinary computation, World Scientific Publishing Co., 1997
  5. Y. G. Xu and G. R. Liu, 'Detection of flaws in composites from scattered elastic-wave field using an improved ${\mu}$-GA and a local optimizer,' Computer methods in applied echanics and engineering, Vol. 191, 2002, pp. 3929-3946 https://doi.org/10.1016/S0045-7825(02)00340-7
  6. 박관순, 고현무, 함대기, '점탄성감쇠기가 설치된 구조물의 통합최적설계' 대한토목학회논문집, 제22권, 제2A호, 2002, pp. 413-422
  7. K. S. Park, H. M. Koh and D. Hahm, 'Integrated optimum design of visco-elastically damped structural systems,' Engineering Structures, Vol. 26, 2003, pp. 581-591 https://doi.org/10.1016/j.engstruct.2003.12.004
  8. 김진구, 방성혁, '점탄성감쇠기를 이용한 비대칭-비탄성구조물의 내진보강', 한국지진공학회논문집, 제6권, 제3호, 2002, pp. 87-93
  9. A. S. Ahlawat and A. Ramaswamy, 'Multi-objective optimal absorber system for torsionally coupled seismically excited structures,' Engineering Structures, Vol. 25, 2003, pp. 941-950 https://doi.org/10.1016/S0141-0296(03)00038-5
  10. 권순덕, 박관순, '동조질량감쇠기를 이용한 공기역학적 불안정 현상의 제어', 대한토목학회논문집, 제23권, 제3A호, 2003, pp. 487-489
  11. Computers & Structures, Inc., SAP2000/Nonlinear User' Manual-Version 7.0, 1997
  12. K. Krishnakumar, Micro-genetic algorithms for stationary and non-stationary function optimization, SPIE:Intelligent control and adaptive systems, Philadelphia, PA, 1989
  13. 열화조건하의 내진안전성재평가 절차확립, 한국원자력안전기술원, KINS/HR-657, 2004. 2