Abstract
This paper presents experimental and analytical studies on long-term behavior of square CFT columns with diaphragm. In order to investigate the effect of the diaphragm on the long~term behavior, experiments for six specimens with two diaphragms and three different column length, and three-dimensional finite element analysis for each specimen have been performed. The finite element models considering the interface behavior between the steel tube and the inner concrete were verified from comparison of the test results with the analysis results. From the test and the analysis results, the following conclusions were obtained. The confinement effect created by the diaphragm does not depends on column length and influences only a part of the whole column that is from the end to the depth which is the same to the width of the column. The shortening of the column with diaphragm which covers more than a half of the cross sectional area of the inner concrete is the same as that of the column under a load applied on the steel tube and the entire section of the inner concrete.
이 연구에서 격막이 설치된 각형 CFT 기둥의 장기거동에 관한 실험과 해석을 수행하였으며, 이를 통해 각형 CFT 기둥의 장기거동에 미치는 격막의 영향을 파악해 보고자 하였다. 격막의 크기에 따라 두 가지, 기둥 길이에 따라 세 가지 변수를 두어 총 6가지의 변수에 대한 실험과 각 실험체에 대한 3차원 유한요소 해석을 수행하였다. 강관과 콘크리트의 계면 거동을 고려한 유한요소 해석은 격막이 설치된 CFT 기둥의 실제 거동을 정확히 모사하였으며, 이를 통해 유한요소 모델링의 정확성이 검증되었다. 실험과 해석 결과로부터 다음과 같은 결론을 얻었다. 격막에 의한 기둥 단부의 구속 효과는 기둥의 길이에 상관없이 CFT 기둥의 단부에서 기둥의 폭만큼 내려간 위치까지이며, 이외의 부분에서 격막 또는 강관에 의한 구속 효과는 나타나지 않았다. 또한 내부 콘크리트 면적의 1/2 이상을 가압할 수 있는 격막이 설치된 각형 CFT 기둥의 장기변형에 의한 축소량은 강관과 콘크리트의 전체 면적을 동시에 가압한 경우의 축소량과 동일하다.