Abstract
Scientific community agrees about the fact that base Isolation provides interesting solutions to minimize the seismic risk. Reliability of such a technique is nowadays proofed by a large number of applications like public buildings, nuclear plants, bridges, etc. This paper reports the results of performance verification tests of the base isolated RC building with the laminated rubber bearings which is manufactured by enterprise in Korea. The shaking table tests were performed using a three story model scaled to 1/3 of the prototype RC apartment building. Several major earthquake records were scaled to different peak ground accelerations and used as input base excitations. Especially in this study, effect of earthquake characteristics on response reduction and effect of the intensity of excitations are studied. Through the verification tests, the validity of the applied base isolaion device and the response reduction effect against earthquakes are confirmed.
면진은 현재 설치 공법의 단순함 그리고 지진하중에 대한 진동제어 효과의 탁월성 등으로 인하여 세계 여러 나라에서 강진으로부터 중요한 건물들을 보호하고, 구조물의 장수명화와 내진성능 향상을 도모하기 위한 실무적인 해결책으로서 받아들여지고 있다. 하지만, 국내의 경우, 재해 시 항상 문제가 되는 정보, 통신, 의료체계 및 사회공공 시설물의 피해로 인한 혼란 방지라는 차원에서 면진 구조의 도입이 종종 거론되고는 있으나 아직까지 구체적인 설계기술은 정착되지 못하고 있는 실정이다. 따라서 본 연구에서는 면진 기술의 국내 기반 구축을 위하여 순수 국내기술에 의해 제작된 면진 장치(NRB)를 채용함에 따른 면진 효과를 실험적으로 검증함으로서, 향후 유사 구조 설계를 위한 기초 자료를 제공하고자 하였으며, 철근콘크리트 구조를 대상으로 지진파의 특성 및 지진동의 입력 레벨에 따른 면진 효과가 US 축소 모델 진동대 실험을 통해 제시되었다. 실험 결과, 본 연구에서 적용한 NRB는 응답가속도의 감소와 층 전단력의 감소가 확실히 관측되어 면진 설계의 기본 개념과 일치하게 건물의 주기를 장주기 영역으로 이동시켜 지진동에 의한 하중 효과를 크게 줄일 수 있는 것으로 나타났으며, 면진 효과는 지진파의 특성에 따라 그 정도의 차가 다르게 나타나는 것으로 확인되었고, 장주기 성분이 많이 포함되어 있는 Mexico지진파와 같은 지진동 고려 시 특히 설계허용수평변위 설정에 주의가 필요한 것으로 나타났다.