초록
In this study turbine flowmeters were used to predict volumetric flow rate of each phase in two-phase, gas-liquid, flowing in a vertical tube. To determine volumetric flow rates of two-phase, air-water, flowing vertically upward through the polycarbonate tube(57mm ID-inside diameter), two turbine flow meters were used. For void fraction measurements, two gamma densitometers were used at each location of the turbine flow meter, one at the upstream and the other at the downstream. It was determined that the turbine flowmeter's outputs were a function of actual volumetric flow rate of each of the two phases. A two-phase flow model was developed.