A High Speed Address Recovery Technique for Single-Scan Plasma Display Panel(PDP)

Single-Scan Plasma Display Panel(PDP)를 위한 고속 어드레스 에너지 회수 기법

  • Published : 2005.09.01

Abstract

A high speed address recovery technique for AC plasma display panel(PDP) is proposed. Replacing GND switch by clamping diode. the recovery speed can be increased by saving GND hold-time and switching loss due to GND switch also becomes also be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Test results with 50' HD single-scan PDP(resolution = 1366$\times$768) show that less than 3sons of recovery time is successfully accomplished and about$54\%$ of the maximum power consumption can be reduced, tracing minimum power consumption curves.

Keywords

References

  1. A. Sobel, 'Plasma Displays,'IEEE Trans. on Plasma Science, vol. 19, no. 6, pp. 1032-1047, December, 1991 https://doi.org/10.1109/27.125029
  2. Y. Sano, A. Takagi, T. Kawada, H. Inoue, and K. Kariya, 'Reduction of Power Consumption in Address Driver ICs for PDP by Power Distributing Method,' SID'01, 1228-1231, 2001 https://doi.org/10.1889/1.1831782