Abstract
In this paper, a sound quality index for the evaluation of the vehicle intake noise was developed through a correlation analysis of the objective measurement and the subjective evaluation. First, intake orifice noise was measured at the wide-open throttle sweep condition. And then, the acoustic transfer function between intake orifice noise and interior noise was measured. Simultaneously, subjective evaluation was carried out with a 10-scale score by 8 special engineers. The correlation analysis between the psychoacoustic parameters derived from the measurement and the subjective evaluation was performed. The most critical factor was determined and the corresponding sound quality index for intake noise was obtained from the multiple factor regression analysis method. Finally, the effectiveness of the proposed index was validated.