참고문헌
- Schilder H. Filling root canals in three dimensions. Dent Clin North Am 11:723-744, 1967.
- Zmener O, Balbachan L. Effectiveness of nickel-titanium files for preparing curved root canals. Endod Dent Traumatol 11:121-123, 1995. https://doi.org/10.1111/j.1600-9657.1995.tb00472.x
- Weine FS. Endodontic therapy. 4th ed., Mosby., St. Louis, p 277, 1989
- Walton R. Current concepts of canal preparation. Dent Clin North Am 36:309-326, 1992.
- Roane J, Sabala C, Duncanson M. The 'balanced force' concept for instrumentation of curved canals. J Endod 11:203-211, 1985. https://doi.org/10.1016/S0099-2399(85)80061-3
- Morgan LF, Montgomery S. An evaluation of the crown-down pressureless technique. J Endod 10:491-498, 1984 https://doi.org/10.1016/S0099-2399(84)80207-1
- Chenail BL, Teplitsky PE. Endosonics in curved root canal. J Endod 11:369-374, 1985. https://doi.org/10.1016/S0099-2399(85)80022-4
- Walsh C, Messee HH, EIDeeb ME. Effect of varying ultrasonic power setting canal preparation. J Endod 16:273-278, 1990. https://doi.org/10.1016/S0099-2399(06)81629-8
- Ingle JI, Taintor JF. Endodontics. 3rd ed., Lea & Febiger., Philadelphia, p 26-37, 1985
- Walia H, Brantley WA, Gerstein, H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 14:346-351, 1988. https://doi.org/10.1016/S0099-2399(88)80196-1
- Espito PT, Cunningham CJ. A comparison of canal preparation with nickel-titanium and stainless steel instruments. J Endod 21:173-176, 1995. https://doi.org/10.1016/S0099-2399(06)80560-1
- 박한수, 이민구, 김종진, 이종엽. ProFile을 이용한 만곡 근관형성시 근관형태에 관한 연구. 대한치과보존학회지 24:633-637, 1999.
- 고현정, 백승호. 수종의 Engine-driven Ni-Ti file과 stainless steel K-file을 이용한 근관 형성 후 근관의 조직형태학적 변화에 관한 연구. 대한치과보존학회지 27:612-621, 2002
-
Calberson FLG, Deroose CAJG, Hommez GMG, Raes H, De Moor RJG. Shaping ability of
$GT^{TM}$ Rotary Files in simulated resin root canals. Int Endod J 35:607-614, 2002. https://doi.org/10.1046/j.1365-2591.2002.00540.x - ElDeeb ME, Boraas JC. The effect of different files on the preparation shape of severely curved canals. Int Endod J 18:1-187, 1985. https://doi.org/10.1111/j.1365-2591.1985.tb00414.x
- Lim KC, Webber J. The validity of simulated root canals for the investigation of the prepared root canal shape. Int Endod J 18:240-246, 1985. https://doi.org/10.1111/j.1365-2591.1985.tb00450.x
- Dummer PMH, Alodeh MHA, Al-Omari MAO. A method for the construction of simulated root canals in clear resin blocks. Int Endod J 24:63-66, 1991. https://doi.org/10.1111/j.1365-2591.1991.tb00809.x
- Schneider SW. A comparison of canal prepararion in straight andcurved canals. Oral Surg 32:271-275, 1971. https://doi.org/10.1016/0030-4220(71)90230-1
- Yun HH, Kim SK. A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 95:228-233, 2003. https://doi.org/10.1067/moe.2003.92
- Hata G, Uemura M, Kato AS, Imura N, Novo NF, Toda T. A comparison of shaping ability using ProFile, GT file, and Flex-R endodontic instruments in simulated canals. J Endod 28:316-321, 2002. https://doi.org/10.1097/00004770-200204000-00014
- Bishop K, Dummer PM. A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals. Int Endod J 30:25-34, 1997. https://doi.org/10.1111/j.1365-2591.1997.tb01095.x
- Coleman CL, Svec TA. Analysis of Ni-Ti versus stainless steel instrumentation in resin simulated canals. J Endod 23:232-235, 1997. https://doi.org/10.1016/S0099-2399(97)80053-2
- Park H. A comparison of Greater Taper files, ProFiles, and stainless steel files to shape curved root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 91:715-718, 2001. https://doi.org/10.1067/moe.2001.114159
- Peter OA, Peter CI, Schonenberger K, Barbaknow F. ProTaper rotary root canal preparation: effects of canal anatomy on final shape analysed by micro CT. Int Endod J 36:86-92, 2003. https://doi.org/10.1046/j.1365-2591.2003.00626.x
- Kavangh D, Lumley PJ. An in vitro evaluation of canals preparation using ProFile .04 and .06 taper instruments. Endod Dent Traumatol 14:16-20, 1998. https://doi.org/10.1111/j.1600-9657.1998.tb00803.x
- Bryant ST, Dummer PM, Pitoni C, Bourba M, Moghal S. Shaping ability of .04 and .06 taper ProFile rotary nickel-titanium instruments in simulated root canals. Int Endod J 32:155-164, 1999. https://doi.org/10.1046/j.1365-2591.1999.00256.x
- 오현정, 홍찬의, 조영범. Ni-Ti Rotary Instruments에 의한 근관형성이 치근단부 근관형태에 미치는 영향. 대한치과보존학회지 22:244-253, 1997.
- Southard DW, Oswald RJ, Natkin E. Instrumentation of curved molar root canals with the Roan technique. J Endod 13:479-489, 1987. https://doi.org/10.1016/S0099-2399(87)80015-8
- Kum KY, Spangberg L, Cha BY, Jung IY, Lee SJ, Lee CY. Shaping ability of three ProFile rotary instrumentation techniques in simulated resin root canals. J Endod 26:719-723, 2000. https://doi.org/10.1097/00004770-200012000-00013
- Thompson SA, Dummer PM. Shaping ability of Lightspeed rotarynickel-titanium instruments in simulated root canals. Part 1. J Endod 23:698-702, 1997. https://doi.org/10.1016/S0099-2399(97)80405-0
피인용 문헌
- in simulated canals with different curvatures vol.32, pp.2, 2007, https://doi.org/10.5395/JKACD.2007.32.2.087