Abstract
The purpose of this study is to investigate the strength and ductility improvement of columns retrofitted by steel-fiber composite plate. Test specimens strengthened by three different materials - steel plate(SP), carbon fiber sheet(CF) and fiber-steel composite plate(CP) - were tested under cyclic lateral load with a constant axial load equal to $20\%$ of the axial compression capacity. The structural capacity of composite plate was good or better than that of other retrofitting materials. Test results from all retrofitted specimens showed that considerably higher retrofitting amount was required for strength enhancement. The ductility of retrofitted columns by composite plate was fairly improved. Also, energy ductility ratio was more effective than displacement ductility ratio for ductility estimation of retrofitted column.
본 연구의 목적은 기둥의 내진성능을 개선하기 위한 연구로서, 섬유-강판이 복합된 보강재를 사용하여 보강기둥의 내력특성을 연구하였다. 이용 가능한 복합판의 보강량을 선정하고, 기존의 탄소섬유와 강판으로 보강한 기둥과 함께 밴드형 보강실험체를 제작하여 일정축력을 받는 기둥에 반복횡하중을 가하여 하중, 변의 및 연성도를 조사하였다. 내진성능의 척도가 되는 변위연성도, 에너지연성도, 누적소산에너지 및 감쇠비를 비교하여 복합판을 사용한 부재의 내력특성을 평가하였다. 연구결과, 복합판을 사용하여 기둥을 보강할 경우에도 다른 보강방법과 같이 양호한 내진성능을 확보할 수 있었다. 또한, 밴드형식으로 보강한 보강실험체의 연성능력은 모두 양호한 편이나, 최대하중 증가를 위해서는 일정량 이상의 보강량이 필요한 것으로 나타났다. 연성도 평가로는 에너지연성도가 변위연성도에 비하여 보강기둥의 연성능력을 잘 나타내었다.