ADSORPTION OF HUMAN RECOMBINANT FIBRONECTIN TO TITANIUM IN VITRO

  • Kim H.J. (Department of Prosthodontics, College of Dentistry, Seoul National University) ;
  • Chang I.T. (Department of Prosthodontics, College of Dentistry, Seoul National University) ;
  • Koak J.Y. (Department of Prosthodontics, College of Dentistry, Seoul National University) ;
  • Heo S.J. (Department of Prosthodontics, College of Dentistry, Seoul National University) ;
  • Yim S.A. (Department of Prosthodontic dentistry, Samsung Medical Center, School of Medicine, Sungkyunkwan University) ;
  • Jang J.H. (Intellectual Biointerface Engineering Center, Seoul National University College of Dentistry)
  • 발행 : 2004.06.01

초록

Statement of problem. Fibronectin mediates its biological effects by binding to integrins on cell membranes through a consensus site including the Arg-Gly-Asp (RGD) sequence within tenth type III module. Purpose. The purpose of our study was to investigate the adsorption affinity of human recombinant fibronectin peptide (hFNIII 9-10) to titanium and to investigate the effect of the surrounding ionic composition on the adsorption process. Material and methods. As for evaluating the affinity of hFNIII 9-10 to Ti, titanium disks were incubated in 40, 80 and $120{\mu}g/ml$ hFNIII 9-10 solution at $37^{\circ}C$ overnight, repectively. As for evaluating the effect of surrounding ionic concentration, hFNIII 9-10 was dissolved in distilled water, phosphate buffered saline and RPMI 1640. Optical density (O.D.) was measured in ELISA reader. Results. The results were as follows; 1. The adsorption of hFNIII 9-10 showed significantly highest mean optical density (O.D.) value in $80{\mu}g/ml$. 2. The difference of ionic composition in DW, PBS and RPMI did not influence the adsorption amount of hFNIII 9-10.

키워드

참고문헌

  1. Kasemo B. Biocompatibility of titanium implants: Surface science aspects. J Prosthet Dent 1983;49:832-837 https://doi.org/10.1016/0022-3913(83)90359-1
  2. Degan IL, Stetsula VI. Consolidation of bone fragments in a constant magnetic field. Ortop Tracmatol Protez 1971;32:45-48
  3. Bruce GK, Howlett CR, Huckstep RL. Effect of a static magnetic field on fracture healing in a rabbit radius. Preliminary results. Clinical orthopaedics and related research 1987;222:300-306
  4. Freedman H. Magnetic counter-influence in full lower denture retention. Dental digest 1941;47:98-503
  5. Gomboltz WR, Wang GH, Horbett TA, Hoffman AS. Protein adsorption to poly(ethylene oxide) surfaces. J Biomed Mater Res 1991;25:1547-1562 https://doi.org/10.1002/jbm.820251211
  6. Tsai CC, Huo HH, Kulkarni PV, Eberhart RC. Biocompatible coatings with high albumin affinity. Asaio Trans 1990;36:M307-M310
  7. Tsai CC, Dollar ML, Constationescu A, Kulkarni PV, Eberhart RC. Performance evaluation of hydoxylated and acylated silicone rubber coatings. Asaio Trans 1991;37:M192-M193
  8. Keogh JR, Velander FF, Eaton JW. Albumin binding surfaces for implantable devices. J Biomed Mater Res 1992;26:441-456 https://doi.org/10.1002/jbm.820260403
  9. Sutherland DS, Forshow PD, Allen GC, Brown IT, Williams KR. Surface analysis of titanium implants. Biomaterials 1993;14:893-899 https://doi.org/10.1016/0142-9612(93)90130-T
  10. Collins JI, Embery G. Adsorption of glycosaminoglycans to commercially pure titanium. Biomaterials 1992;13:548-552 https://doi.org/10.1016/0142-9612(92)90107-Y
  11. Jang JH, Ku Y, Chung CP, Heo SJ. Enhanced fibronectin-mediated cell adhesion of human osteoblast by fibroblast growth factor, FGF-2. Biotechnology letters 2002;24:1659-1663 https://doi.org/10.1023/A:1020617904251
  12. Nygren H, Tengvall P, Lundstrom I. The initial reactions of Ti$O_2$ with blood. J Biomed Mater Res 1997;34:487-492 https://doi.org/10.1002/(SICI)1097-4636(19970315)34:4<487::AID-JBM9>3.0.CO;2-G
  13. MacDonald DE, Deo N, Markovic B, Stranick M, Somasundaran P. Adsorption and dissolution behavior of human plasma fibronectin on thermally and chemically modified titanium dioxide particles. Biomaterials 2002;23:1269-1279 https://doi.org/10.1016/S0142-9612(01)00317-9
  14. MacDonald DE, Markovic B, Boskey AL, Somasundaran P. Physico-chemical properties of human plasma fibronectin binding to well characterized titanium dioxide. Colloids Surf 1998;B11:131-139
  15. Cuypers PA, Hermens WT, Hemker HC. Ellipsometry as a tool to study protein films at liquid- solid interfaces. Anal Biochem 1978;84:56-57 https://doi.org/10.1016/0003-2697(78)90483-9
  16. Sundgren JE, Bodo P, Ivarsson B, Lundstrom I. Adsorption of fibronigen on titanium and gold surfaces studied by ESCA and ellipsometery. J Colloid Interface Sci 1986;113:530-543 https://doi.org/10.1016/S0021-9797(86)90446-7
  17. Ruoslahti E, Pierschbacher MD. Mew perspectives in cell adhesion: RGD and integrins. Science 1987;238:491-497 https://doi.org/10.1126/science.2821619
  18. Klinger A, Steinberg D, Kohavi D, Sela MN. Mechanism of adsorption of human albumin to titanium in vitro. J Biomed Mater Res 1997;36:387-392 https://doi.org/10.1002/(SICI)1097-4636(19970905)36:3<387::AID-JBM13>3.0.CO;2-B
  19. Goldstin AS, DiMilla PA. Effect of adsorbed fibronectin concentration on cell adhesion and deformation under shear on hydrophobic surfaces. J Biomed mater Res 2002;59:665-675 https://doi.org/10.1002/jbm.1276
  20. Clark EA, Brugge JS. Integrins and signal transduction pathways: the road taken. Science 1995;268:233-239 https://doi.org/10.1126/science.7716514
  21. Singer II, Kawka DW, Scott S, Mumford RA, Lark MW. The fibronectin cell attachment sequence Arg-Gly-Asp-Ser promotes focal contact formation during early fibroblast attachment and spreading. J Cell Biol 1987;104:573-584 https://doi.org/10.1083/jcb.104.3.573