Journal of the Korean Solar Energy Society (한국태양에너지학회 논문집)
- Volume 24 Issue 4
- /
- Pages.77-87
- /
- 2004
- /
- 1598-6411(pISSN)
- /
- 2508-3562(eISSN)
A study on the efficiency of sloped type Double-skin System for the Curtailment of Heating/Cooling Load
냉난방부하 절감을 위한 경사형 이중외피시스템의 성능연구
- An, Hyung-Jun (Dept. of Architecture, Graduate School, Kwang woon University) ;
- Kim, Young-Tag ;
- Choi, Chang-Ho (Dept. of Architecture, Kwang woon University) ;
- Lee, Hyn-Woo (Dept. of Architecture, Kwang woon University)
- Published : 2004.12.30
Abstract
BIPV or double skin applied to the surface of the building, power and thermal load cannot both be increased. In the case of BIPV, because it is applied to the facade, incident solar energy decreases and efficiency drops off. The system in this paper complements these disadvantages and aims to decrease the heating & cooling load by transforming solar energy to electronic and thermal energy. The research in this paper is about the applicability of the clear PV attached double-skin system. And the PV electronic generation and the factors that affect the heating & cooling load such as the daily radiation, sun shading ratio, heating & cooling load, daylight luminance and glare distributions in the building are simulated.