DOI QR코드

DOI QR Code

Seismic Design of Reduced Beam Section (RBS) Steel Moment Connections with Bolted Web Attachment

보 웨브를 볼트 접합한 RBS 철골모멘트접합부의 내진설계

  • Published : 2004.06.01

Abstract

Recent test results on reduced beam section (RBS) steel moment connections showed that specimens with a bolted web tended to perform poorly due to premature brittle fracture of the beam flange at the weld access hole. The measured strain data appeared to imply that a higher incidence of base metal fracture in bolted-web specimens is related to, at least in part, the increased demand on the beam flanges due to the web bolt slippage and the actual load transfer mechanism which is completely different from that usually assumed in connection design. In this paper, the practice of providing web bolts uniformly along the beam depth was brought into question. A new seismic design procedure, which is more consistent with the actual load path identified from the analytical and experimental studies, was proposed together with improved connection details.

최근에 수행된 보 플랜지 절취형 (Reduced Beam Section, RBS) 내진 철골모멘트접합부의 실험 결과에 의하면, 보 웨브를 볼트 접합한 시험체는 보 웨브를 용접 접합한 시험체에 비해서 조기에 스캘럽을 가로지르는 취성파단이 발생하는 열등한 내진성능을 보였다. 실험결과에 의할 때, 이러한 접합부 취성파괴가 발생하는 주요 원인은 웨브 볼트의 슬립과 고전 휨이론에 의한 예측과는 전혀 다른 응력 전달메카니즘에 의한 스캘럽 부근의 응력집중 때문으로 사료된다. 이는 고전 휨이론에 기초한 전통적 보 웨브 볼트접합부의 설계법을 재검토할 필요가 있음을 시사하는 것이다. 본 연구를 통하여 고전 휨이론에 기초한 현행의 보 웨브 설계법에 문제가 있음을 지적하였다. 실험 및 해석결과를 바탕으로 RBS 접합부의 실제 응력전달경로에 부합되는 새로운 보 웨브 볼트접합 설계법을 제안하였다.

Keywords

References

  1. Chen, S. J., Yeh, C. H., and Chu, J. M 'Ductile steel beam-to-column connections for seismic resistance,' J. Struct. Engrg., ASCE, 122(11), 1996, pp. 1292 - 1299 https://doi.org/10.1061/(ASCE)0733-9445(1996)122:11(1292)
  2. Plumier, A. 'The dogbone: back to the future.' Engrg. J. 34(2), 1997, pp. 61 - 67
  3. Zekioglu, A., Mozaffarian, H., Chang, K. L., and Uang, C.-M. 'Designing after Northridge,' Modern Steel Constr., 37(3), 1997, pp. 36 - 42
  4. Engelhardt, M. D., Winneberger, T., Zekany, A. J., Potyraj, T. J., (1998). 'Experimental Investigations of Dogbone Moment Connections,' Engrg. J., AISC, 35(4), Fourth Quarter, 1998, pp. 128 - 139
  5. Jones, SI. L., Fry, G. T., and Engelhardt, M. D., 'Experimental Evaluation of Cyclically Loaded Readuced Beam Section Moment Connections,' J. Struct. Engrg., ASCE, 128(4), 2002, pp. 441-451 https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(441)
  6. Gilton, C. S. and Uang, C.-M., 'Cyclic Response and Design Recommendations of Weak-Axis Reduced Beam Section Moment Connections,' J. Struct. Engrg., ASCE, 128(4), 2002, pp. 452-463 https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(452)
  7. Chi, B. and Uang, C.-M., 'Cyclic Response and Design Recommendations of Reduced Beam Section Moment Connections with Deep Columm,' J. Struct. Engrg., ASCE, 128(4), 2002, pp. 464-473 https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(464)
  8. Lee, C.-H., Jeon, S.-W., Kim, J.-H., and Uang, C.-M., 'Effects of Panel Zone Strength and Beam Web Connection Method on Seismic Performance of Reduced Beam Section Steel Moment Connections, 'submitted to J. Struct. Engrg., ASCE, 2003
  9. Lee, C.-H., Jeon, S.-W., Kim, J.-H., 'Cyclic seismic testing of reduced beam section steel moment connections: effects of panel zone strength and beam web connection type,' Earthquake Engineering Society of Korea, 7(3), 2003, pp. 69-77 https://doi.org/10.5000/EESK.2003.7.3.069
  10. Iwankiw, N., 'Ultimate strength consideration for seismic design of the reduced beam section (internal plastic hinge),' Engrg. J. 34(1), 1997, pp. 3-16
  11. SAC 'Seismic design criteria for new moment-resisting steel frame construction,' Report No. FEMA 350, SAC Joint Venture, Sacramento, Calif, 2000
  12. Tsai, K. C. and Popov, E. P., 'Steel beam-column joints in seismic moment resisting frames,' EERC Report, UCB/EERC-88/19, Univ. of California., Berkeley, 1988
  13. Gael, S. C., Stojadinovic, B., and Lee, H.-K., 'Truss analogy for steel moment connections.,' Eng. J., 34(2), 1997, pp. 43 - 53
  14. HKS, ABAQUS User's Manual, Version 6.2 Hibbit, Karlson & Sorenson, Inc, 2001