초록
This paper addresses an analysis for a railway data transmission protocol-Ethernet based data transmission between the CTC(Centralized Traffic Control System) and the SCADA(Supervisory Control and Data Acquisition) system. Fame error rates of the data transmissions are calculated and compared for the two cases that the CTC/SCADA has an extra data transmission error control(CRCI6) besides the inherent error control of the Ethernet(CRC32), and that the CTC/SCADA has no extra data transmission error control. With simulation results it has been verified that the extra data transmission error control(CRC16) contributes to lowering the frame error rate.