초록
The object of this study is to investigate the effect of compounded welding through the AE(Acoustic Emission) characteristics for weld HAZ(Heat Affected Zone) under the static tensile test. This study was carried out an SWS 490A, high tension steel for electric shield metal arc welding(SMAW), $CO_2$ gas arc welding and TIG welding. Data displays are based on the measured parameters of the AE signals, along with environmental variables such as time and load. The accumulated AE event curve of HAZ definitely have the point of inflection subject to tensile test. The results of the tensile test of HAZ come out electric shield arc welding >$CO_2$ gas arc welding>TIG welding in case of single welding, but generally the tensile test of HAZ come out electric shield arc welding> TIG welding > $CO_2$ gas arc welding. These history plots give us useful and powerful information to analyze the results of material evaluation testing.