References
- Bagby M, Marshall SJ, Marshall GW. Metal ceramic compatibility: A review of the literature. J Prosthet Dent 1990;63:21-5 https://doi.org/10.1016/0022-3913(90)90259-F
- Dent RJ, Preston JD, Moffa JP. Effect of oxidation on ceramometal bond strength. J Prosthet Dent 1982;47:59-62 https://doi.org/10.1016/0022-3913(82)90243-8
- Moffa JP. Alternative dental casting alloys. Dent Clin North Am 1983;27:733-46
- Moffa JP, Lugassy AA, Guckes AD, Gottleman L. An evaluation of nonprecious alloys for use with porcelain veneers. Part I . Physical properties. J Prosthet Dent 1973;30:424-31 https://doi.org/10.1016/0022-3913(73)90164-9
- Kelly JR, Rose TC. Nonprecious alloys for use in fIxed prosthodontics: A literature review. J Prosthet Dent 1983;49:363 https://doi.org/10.1016/0022-3913(83)90279-2
- Rosenstiel SF, Land MF, Fujimoto J. Contemporary fIxed prosthodontics. 3rd ed. St. Louis:Mosby;2001. p.488-512
- Kupper H. Pure titanium as an alternative material in restorative dentistry. QDT 1992;143-52
- Wang RR, Fenton A. Titanium for prosthodontic applications: A review of the literature. Quintessence Int 1996;27:401-8
- Kasemo B. Biocompatibility of titanium implants: Surface science aspects. J Prosthet Dent 1983;49:832-7 https://doi.org/10.1016/0022-3913(83)90359-1
- Parr GR, Gardner LK, Toth RW. Titanium: the mystery metal of implant dentistry. Dental materials aspects. J Prosthet Dent 1985;54:410-4
- Bergman B, Bessing C, Ericson G. et al.A 2-year follow-up study titanium crowns. Acta Odontol Scand 1990;48:113-7 https://doi.org/10.3109/00016359009005866
- Blackman R, Barghi N, Tran C. Dimensional changes in casting titanium removable partial denture frameworks. J Prosthet Dent 1991;65:309-15 https://doi.org/10.1016/0022-3913(91)90181-U
- Bridgeman JT, Marker VA, Hummel SK, et al. Comparison of titanium and cobaltchromium removable partial denture clasps. J Prosthet Dent 1997;78:187-93 https://doi.org/10.1016/S0022-3913(97)70124-0
- Eugene P. Titanium and titanium alloy as dental materials. Int Dent J 1993;43:245-53
- Christer B, Maud B. The castability of unalloyed titanium in three different casting machines. Swed Dent J 1992;16:109-13
- AI-Mesmar HS, Morgano SM, Mark LE. Investigation of the effect of three sprue designs on the porosity and the completeness of titanium cast removable partial denture frameworks. J Prosthet Dent 1999;82:15-21 https://doi.org/10.1016/S0022-3913(99)70126-5
- Taira M, Moser JB, Greener EH. Studiesof Ti alloys for dental castings. Dent Mater 1989;5:45-50 https://doi.org/10.1016/0109-5641(89)90093-6
- Low D, Mori T. Titanium full crown casting: thermal expansion of investments and crown accuracy. Dent Mater 1999;15:185-90 https://doi.org/10.1016/S0109-5641(99)00031-7
- Zinelis S. Effect of pressure of helium, argon, kryton, and xenon on the porosity, microstructure, and mechanical properties of commercially pure titanium castings. J Prosthet Dent 2000;84:575-82 https://doi.org/10.1067/mpr.2000.109479
- Muller HJ, Giuseppetti AA, Waterstrat RM. Phosphate-bonded investment materials for titanium casting. 'Abstract 2072' J Dent Res 1990;69(special issue)
- Watanabe I. Watkins JH. NakajimaH.et al. Effect of pressure difference on the quality of titanium casting. J Dent Res 1997;3:773-9
- Syverud M, Hero H, Mold filling of Ti castings using investments with different gas permeability. Dent Mater 1995;11:14-8
- Hero H, Syverud M, Waali M. Mold filling and porosity in casting of titanium. Dent Mater 1993;9:15-8 https://doi.org/10.1016/0109-5641(93)90098-B
- Andersson M, Bergman B, Bessing C, et al. Clinical results with titanium crowns fabricated with machine duplication and spark erosion. Acta Odontol Scand 1989;47:279-86 https://doi.org/10.3109/00016358909007713
- Sjogren G, Andersson M, Bergman M. Laser welding of titanium in dentistry. Acta Odontol Scand 1988;46:247-53 https://doi.org/10.3109/00016358809004774
- Einar B, Warren CW, Geir D, Edward RD. Mechanical properties of laser-welded cast and wrought titanium. J Prosthet Dent 1995;74:250-7 https://doi.org/10.1016/S0022-3913(05)80131-3
- Leong D, Chai J, Lautenschlager E, Gilbert J. Marginal fit of machine-milled titanium and cast titanium single crowns. Int J Prosthdont 1994;7:440-7
- Valderrama S, Rokel NV, Andersson M, et al. A comparison of the marginal and internal adaptation of titanium and gold-platinurn-palladium metal ceramic crowns. Int J Prosthdont 1995;8:29-37
- Togaya T, Suzuki M, Tsutsumi S. Ida K. An application of pure titanium to the metal porcelain system. Dent Mater J 1983;2:210-9 https://doi.org/10.4012/dmj.2.210
- Kononen M, Kivilahti J. Bonding of low fusing dental porcelain to commercially pure titanium. J Biomed Mater Res 1994;28:1027-35 https://doi.org/10.1002/jbm.820280907
- Kimura H, Horning CJ, Okazaki M, Takahashi J. Thermal compatibility of titanium-porcelain system. J Osaka Uni Dent Sch 1990;30:43-52
- Hanses G, Smedberg JI, Ekenback J, Nilner K. A 2-year follow-up study of machine fabricated titanium bridges. 'IADR abstract 045' J Dent Res 2001;80(special issue)
- Kaus T, Proster L, Weber H. Clinical follow-up study of ceramic veneered itanium restorations-Three-year results. Int J Prosthodont 1996;9:9-15
- Nilson H, Bergman B, Bessing C, et al. Titanium copings veneered with procera ceramics: A longitudinal clinical study. Int J Prosthodont 1994;7:115-9
- Walter M, Reppel PD, Boning K, Freesmeyer WB. Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures. J Oral Rehabil 1999;26:91-6 https://doi.org/10.1046/j.1365-2842.1999.00373.x
- International Standard Organization(ISO)/DIS 9693 (1999) Dental ceramic fused to metal restorative materials. Draft International Standard
- Knap FJ, Ryge G. Study of bond strength of dental porcelain fused to metal. J Prosthet Dent 1966;45:1047-51
- Shell JS, Nielsen JP. Study of the bond between gold alloys and porcelain. J Dent Res 1962;41:1424-37 https://doi.org/10.1177/00220345620410062101
- Hautaniemi JA, Hero H, Juhanoja JT. On the bonding of porcelain on titanium. J Mater Sci 1992;3:186-91
- Kimura H, Horning CJ, Okazak MI. Oxidation effect on porcelain titanium interface reation and bond strength. Dent Mater J 1990;9:91-9 https://doi.org/10.4012/dmj.9.91
- Adachi M, Macket JR, Parry EE, Fairhurst CW. Oxide Adherence and Porcelain Bonding to titanium and Ti-6AI-4V Alloy. J Dent Res 1990;69:1230-5 https://doi.org/10.1177/00220345900690060101
- Anusavice KJ, Dehoff PH, Gray A, Lee RB. Delayed crack development in porcelain due to incompatibility stress. J Dent Res 1988;65:1086-91
- Probster L, Maiwald U, Weber H. Three-point bending strength of ceramics fused to cast titanium. Eur J Oral Sci 1996;104:313-9 https://doi.org/10.1111/j.1600-0722.1996.tb00083.x
- Saadet A, Semih B. Bond strength of three porcelains to two forms of titanium using two firing atmosphere. J Prosthet Dent 2000;84:567-74 https://doi.org/10.1067/mpr.2000.110267
- Yilmaz H, Dincer C. Comparison of the bone compatibility of titanium and an Ni-Cr alloy to dental porcelain. J Dent 1999;27:215-22 https://doi.org/10.1016/S0300-5712(98)00045-1
- Derand T, Hero H. Bond strength of porcelain on cast vs. wrought titanium. Scan J Dent 1992;100:184-8
- Pang IC, Gilbert JL, Chai J ,Lautenschlager EP. Bonding characteristics of low-fusing porcelain bonded to pure titanium and palladium-copper alloy. J Prosthet Dent 1995;73:17-25 https://doi.org/10.1016/S0022-3913(05)80267-7
- Wight TA, Bauman JC, Pelleu GB. An Evaluation of four variables affecting the bond strength of porcelain to nonprecious alloy. J Prosthet Dent 1977;37:570-7 https://doi.org/10.1016/0022-3913(77)90172-X
- Guinn III JW, Griswold WH, Vermilyea SG.The effect of cooling rate on the apparent bond strength of porcelain-metal couples. J Prosthet Dent 1982;48:551-4 https://doi.org/10.1016/0022-3913(82)90361-4
- Schaffer SP. An approach to determining the bond strength of ceramo-metal systems. J Prosthet Dent 1982;48:282-4 https://doi.org/10.1016/0022-3913(82)90011-7
- Caputo AA, Dunn B, Resibick MH. A flexural method for evaluation of metal-ceramie bond strength. J Prosthet Dent 1977;56:1501-6
- Anusavice KJ, Dehoff PH, Fairhurst CW. Comparative Evaluation of ceramic-metal bond tests using finite element stress analysis. J Dent Res 1980;59:608-13 https://doi.org/10.1177/00220345800590030901
- Lenz J, Schwarz S, Schwickerath H, Spemer F, Schafer A. Bond strength of metaI-ceramic system in three-point flexure bond test. J Appl Biomater 1995;6:55-64 https://doi.org/10.1002/jab.770060108
- Barghi N, Lorenzana RE. Optimum thickness of opaque and body porcelain. J Prosthet Dent 1982;48:429-3 https://doi.org/10.1016/0022-3913(82)90080-4
- McLean JW. Dental ceramics. Chicago:Quintessence: 1983. p.13-49
- Kvam K, Derand T, Austrheim EK. Fracture toughness and flexural strength of dental ceramics for titanium. Biomater 1995;16:73-6 https://doi.org/10.1016/0142-9612(95)91099-K
- Esquivel JF, Chai J, Wozniak WT. The physical properties of low-fusing porcelains for titanium. lnt J Prosthodont 1996;9:563-71
- Hsu CC, Lee YP, Hong CC. Effect of different ceramic firing cycles on cp titanium ceramic flexural bond strength under cyclic fatigue loading. 'IADR abstract 1088' J Dent Res 2001;80(special issue)
- Kimura H, Horng CJ, Okazaki M,Takahashi J. Effects of retention and bonding agent on bond strength of the titanium-porcelain system. J Osaka Uni Dent Sch 1991;31:23-32