DOI QR코드

DOI QR Code

The Use of Hook Plate on the Management of Unstable Neer II Lateral End Fracture of The Clavicle

불안정한 Neer II형 원위쇄골 골절의 치료에서 Hook 금속판의 이용

  • Ko, Sang-Hun (Department of Orthopedic Surgery, Ulsan University Hospital, University of Ulsan, College of Medicine) ;
  • Cho, Sung-Do (Department of Orthopedic Surgery, Ulsan University Hospital, University of Ulsan, College of Medicine) ;
  • Park, Moon-Soo (Department of Orthopedic Surgery, Ulsan University Hospital, University of Ulsan, College of Medicine) ;
  • Ryu, SuGoo (Department of Orthopedic Surgery, Ulsan University Hospital, University of Ulsan, College of Medicine)
  • 고상훈 (울산대학교 의과대학 정형외과학교실) ;
  • 조성도 (울산대학교 의과대학 정형외과학교실) ;
  • 박문수 (울산대학교 의과대학 정형외과학교실) ;
  • 류석우 (울산대학교 의과대학 정형외과학교실)
  • Published : 2003.12.01

Abstract

Purpose: Unstable Neer type II lateral end fracture of clavicle may be required operation. The purpose of this study is the effectiveness of the use of Hook plate in the management of unstable Neer type II fractures. We preliminary reported the results of Unstable Neer type II lateral end fracture of clavicle using by Hook plate. Material and Methods: From May 1998 to May 2002, we operated 6 cases unstable Neer type II lateral end fracture of clavicle with Hook plate by one surgeon. We checked radiologic evaluation and disappearance of pain per 1 week, and evaluated improvement of range of motion per 2 week. And we followed up at each interval 3 months,6 months, 12 months and after that per 6months interval, at that each time we checked stress radiogram of shoulder and functional evaluation. The shoulder function was evaluated using Modified Shoulder Rating Scale (MSRC) for Distal Clavicle Fracture and UCLA score. Average follow up was on 37.2 (12∼57) months. Results: All 6 patients were regained satisfactory function. Average MSRC for distal clavicle fracture was 17.3 (15∼20) and average UCLA score was 33.2 (31∼35) at last follow up. Conclusion: There are many advantage of the use of Hook plate on management of unstable Neer II distal clavicle fracture in spite of several disadvantage. There have not yet been reported in our country. So we obtained good to excellent clinical result in surgical treatment of 6 cases on type II displaced lateral end fracture of the clavicle. But we think that more cases will be review and longer follow up will be needed in the future.

Keywords

References

  1. 김영민, 정문상, 성상철: 골절학, 제4장 견갑부 골절 및 탈구, 213-214, 2001.
  2. Chen CH, Chen WJ, Shin CH: Surgical treatment for distal clavicle fracture with coracoclavicular ligament disruption. J Trauma, 52(1):72-8, 2002. https://doi.org/10.1097/00005373-200201000-00013
  3. Edwards DJ, Kavanagh TG, Flannery MC: Fractures of the distal clavicle: a case for fixation. Injury, 1992;23(1):44-6. https://doi.org/10.1016/0020-1383(92)90125-C
  4. Ellman H, Hanker G, Bayer M: Repair of the Rotator Cuff, End-Result Study of Factors Influencing Reconstruction, J Bone Joint Surg, 67A:1136-1144, 1986.
  5. Ernst S, Nikolaus S, Karl H, Andrea B: Repair of Complete Acromioclavicular Separations Using the Acromioclavicular-Hook Plate. Clin Orthop, 314:134-142, 1995.
  6. Faraj AA, Ketzer B: The use of a hookplate in the management of acromioclavicular injuries. Report of ten cases. Acta Orthop Belg, 67(5):448-51, 2001.
  7. Flinkkila T, Ristiniemi J, Hyvonen P, Hamalainen M: Surgical treatment of unstable fractures of the distal clavicle: a comparative study of Kirschner wire and clavicular hook plate fixation. Acta Orthop Scand,;73(1):50-3, 2002. https://doi.org/10.1080/000164702317281404
  8. Gordon WN, Mark KB: Acromioclavicular Joint Injuries and Distal Clavicular Fractures. J AM Acad Orthop Surg, 5:11-18, 1997.
  9. Guy DK, Wirth MA, Griffin JL, Rockwood CA Jr.: Reconstruction of chronic and complete dislocations of the acromioclavicular joint. Clin Orthop, 347:138-49, 1998.
  10. Habernek H, Weinstabl R, Schmed L, Fialka C: A hook plate for treatment of acromioclavicular joint separation: indication, technique, and result after one year. The J Trauma, 35(6): 893-901, 1993. https://doi.org/10.1097/00005373-199312000-00016
  11. Henkel T, Oetiker R, Hackenbruch W: Treatment of fresh Tossy III acromioclavcular joint dislocation by ligament suture and temporary fixation with the clavicular hooked plate. Swiss Surg, 3(4):160-6, 1997.
  12. Kao FC, Chao EK, Chen CH, Yu SW, Chen CY, Yen CY: Treatment of distal clavicle fracture using Kirschner wires and tension-band-wires. J Trauma, 51(3):522-5, 2001. https://doi.org/10.1097/00005373-200109000-00016
  13. Katznelson A, Nerubay J, Oliver S: Dynamic fixation of the avulsed clavicle. J Trauma, 16(10):841-4, 1976. https://doi.org/10.1097/00005373-197610000-00017
  14. Levy O: Simple, minimally invasive surgical technique for treatment of type 2 fractures of the distal clavicle. J Shoulder Elbow Surg, 12(1):24-8, 2003. https://doi.org/10.1067/mse.2003.128564
  15. Mall JW, Jacobi CA, Philipp AW, Peter FJ: Surgical treatment of fractures of the distal clavicle with polydioxanone suture tension band wiring: an alternative osteosynthesis. J Orthop Sci, 7(5):535-7, 2002. https://doi.org/10.1007/s007760200095
  16. Mizue F, Shirai Y, Ito H: Surgical treatment of comminuted fractures of the distal clavicle using Wolter clavicular plates. J Nippon Med Sch, 67(1):32-4, 2000. https://doi.org/10.1272/jnms.67.32
  17. Neer CS Jr.: Fracture of the distal clavicle with detachment of coracoclavicular ligaments in adults. J Trauma, 3;99-110, 1963. https://doi.org/10.1097/00005373-196303000-00001
  18. Neer CS II: Fracture of the distal third of the clavicle. Clin Orthop, 58:43-50, 1968.
  19. Parkes JC, Deland JT: A three-part distal clavicle fracture. J Trauma, 23(5):437-8, 1983. https://doi.org/10.1097/00005373-198305000-00016
  20. Zenni EJ Jr, Krieg JK, Rosen MJ.: Open reduction and internal fixation of clavicular fractures. J Bone Joint Surg, 63A:147-51, 1981.

Cited by

  1. Hook Plate Fixation for Unstable Distal Clavicle Fractures: A Prospective Study vol.14, pp.1, 2011, https://doi.org/10.5397/CiSE.2011.14.1.006
  2. Usefulness of the Additional K-Wire Fixation and Suture for Reinforce the Treatment of Distal Clavicle Fracture Using Modified Tension Band Wiring vol.29, pp.2, 2016, https://doi.org/10.12671/jkfs.2016.29.2.107
  3. Operative Treatment of Distal Clavicle Fracture with Acromioclavicular Joint Injury vol.14, pp.1, 2011, https://doi.org/10.5397/CiSE.2011.14.1.059