In this study, the distributions of internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were systematically measured at a mechanically ventilated broiler houses during summer season, with local weather data. The analysis was focused on the suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens and decrease of productivity In the mechanically ventilated broiler house, the difference between measured and recommended air temperatures(suitability) was 10.4C in maximum during the summer time. The difference of air temperature in the house between day and night was
국내 대형육계사의 최적 환기 구조 개발을 위한 주요환경요소의 적정성, 안정성, 균일성 등의 기초 자료가 매우 부족한 실정이어서, 강제 환기식 육계사에서 하절기동안 기상데이터와 함께 육계사 내 주요 환경변수를 시간별로 측정하였다. 이번 실험을 통하여 앞으로 시설 및 환기구조 개선을 통한 열적 스트레스 감소 등 닭 생산성을 더 높일 수 있는 여지가 많이 있다는 것을 알 수 있었다 이 연구의 목적은 강제 환기식 육계사내의 주요 환경요소 및 환기 효율성 등을 정확하게 이해하고, 현 시설 및 환기구조상의 문제점을 파악하고자 함이었다. 이 자료는 앞으로 공기유동분석 등 공학적 접근을 통한 시설 및 환기구조 개선연구를 위한 기초 자료로 활용될 계획이며, 실험결과는 다음과 같다. 1. 계사 내 평균온도는 적정온도와 최대