회생차량을 포함한 급전시스템 해석 알고리즘

The Computer Algorithm for DC Traction Power Supply System Analysis Including Regenerative Braking Vehicles

  • 발행 : 2003.11.01

초록

Nowadays traction motors in the urban rail transit vehicle are controlled by VVVF inverter and have capability of regenerative braking. The algorithms to deal with the regenerating vehicle in simulation for the DC traction power supply is introduced in this paper. Substations have to be separated from the system to represent reverse biased rectifiers in substations. The model of the trains in regenerative braking has to be changed from the ideal current source to the constant voltage source since the train input voltage has to be controlled below the certain train maximum voltage. Some mismatches are unevitable because the constraint of the regenerated power can not be imposed with the constant voltage source. The mismatches represent the unused regenerated power. A computer program is developed to verify the validity of the algorithm. The test run result shows the program behaves as it is expected and proves the algorithm's validity.

키워드

참고문헌

  1. C.T. Tse K.L. Chan S.L. Ho, 'Tracking Techniques for DC Traction Loadflow' International Conference on Developments in Mass Transit Systems, Conference publication No 543, IEE20-23 April 1998
  2. Y.Cai, M.R.Irving, S.H.Case, 'Iterative techniques for the solution of complex DC-rail-traction systems including regenerative braking', IEE Proc. C., vol 142,1995 https://doi.org/10.1049/ip-gtd:19952098