A Study on the Characteristics an Azeotropic Mixture Combined with CF_{3}I and a Refrigerant for Air-Conditioner HFC-152a and HFC-152a

  • Lee, Jong-In (Department of Automobile Engineering, Chosun College of Science) ;
  • Kwon, Il-Wook (Department of Mechanical Engineering, Chosun University) ;
  • Ha, Ok-Nam (Department of Mechanical Engineering, Chosun University)
  • Published : 2003.09.01

Abstract

In these days, environmental concerns have been increased throughout the industry and community worldwide. To prevent the ozone depletion, ozone depletion potential of a refrigerant must be zero. Simultaneously, a refrigerant with low GWP (global warming potential) is very demanding to reduce green house effect. Chlorine-free HFC-l34a is a refrigerant widely used for automotive air-conditioning system because its destruction potential is ecologically zero. Although HFC-l34a has no ozone depletion potential, its global warming potential is so high that it is not considered as a perfect alternative refrigerant that is acceptable for long-term use. In this paper, experimental measurement has been carried out to analyze the performance characteristics of automotive air-conditioning system using HFC-152a, which has low GWP and zero ODP. Also mixed refrigerant that is composed of HFC-152a and $CF_3$ was applied to investigate an alternative possibility for the automotive air-conditioning system. As a result of this study, we could draw following conclusions; With respect to the variation of the rotational speed of compressor, outside air temperature and flow rate, the heat amount of evaporator and compressor and performance coefficient was varied.

Keywords

References

  1. Soloman, S. and Wuebbles, D., 1994, ODPs, GWPs, and Future Chlorine/Bromine Loading, Scientific Assessment of Ozone Depletion, pp. 131-136
  2. Jung, D. S., 1996, Development trend of new alternative refrigerant, The Society of Airconditioning and Refrigerating Engineers of Korea, Vol. 25, No. 6, pp. 479-488
  3. Lee, H. C., Park, B. J., Jung, D. S., Oh, S. J. and Jung, E. K., 1999, Performance of alternative refrigerant mixtures containing $CF_3I$ for CFC12 in automobile air conditioners, The Society of Air-conditioning and Refrigerating Engineers of Korea, Proceedings of the SAREK '99 Summer Annual Conference (I), pp. 219-224
  4. Han, J. S., Youn, J. G. and Won, S. P., 1999, A study on performance characteristic of a new alternative refrigerant replacing HFC-134a, The Society of Air-conditioning and Refrigerating Engineers of Korea, Proceedings of the SAREK '99 Summer Annual Conference (I), pp. 219-224
  5. Montreal Protocol on Substances that Deplete the Ozone Layer, 1987, United Nations Environmental Programme(UNEP), New York, p. 15
  6. Mclinden, M., Klein, S., Lemmin, E. and Peskin, A., 1998, NIST Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures (REFPROP) Version 6.0, National Institute of Standards and Technology, Boulder, CO, U.S.A.
  7. Knobler, C. M., 1987, Volumetric Properties of Gaseous Mixtures, in Specialist Periodical Reports, Chemical Thermodynamic, Vol. 2, pp. 199-205
  8. Ebenr, T. and Halozan, H., 1994, Testing the Available Alternative-An Examination of R-134a, R-152a and R-290, lEA HPC Newsletter, Vol. 12, No.1, Sittard, The Netherlands
  9. Tanikawa, S., Kabata, Y., Sato, H. and Watanabe, K., 1990, J. Chem. Eng. Data, 35 (4), p. 381
  10. McLinden, M. O., 1990, Int. J. Refrig., 13 (3), p. 149
  11. McLinden, M. O., Gallagher, J. S., Weber, L. A., Morrison, G., Ward, D., Goodwin, A. R. H., Moldover, M. R., Schmidt, J. W., Chae, H. B., Bruno, T. J., Ely, J. F. and Huber, M. L., 1989, ASHRAE Trans., 95 (2), p. 263
  12. Thinh, T. P., Duran, J. L., Ramalho, R. S. and Kaliagujne, S., 1971, Hydrocarbon Processing, 50 (1), p. 98