The objective of the present study was to investigate the characteristics of flow and wall shear stress under steady and pulsatile flow in the aneurysm. The numerical simulation using the software were carried out for the diameter ratios ranging from 1.5 to 3.0, Reynolds number ranging from 900 to 1800 and Womersley number, 15.47. For steady flow, it was shown that a recirculating vortex occupied the entire bulge with its core located closer to the distal end of the bulge and the strength of vortex increased with increase of the Reynolds number and diameter ratio. The position of a maximum wall shear stress was the distal end of the aneurysm regardless of the Reynolds number and diameter ratios. For the pulsatile flow, a recirculating flow at the bulge was developed and disappeared for one period and the strength of vortex increased with the diameter ratio. The maximum values of the wall shear stress increased in proportion to the diameter ratio. However, the position of a maximum wall shear stress was the distal end of the aneurysm regardless of the diameter ratios.

키워드

참고문헌

  1. Budwig, R. D., Elger, D., Hooper, H. and Slippy, Journal, 1993, 'Steady Flow in Abdominal Aortic Aneurysm Models,' Journal of Biomechanical Engineering, Vol. 115, pp. 418-423 https://doi.org/10.1115/1.2895506
  2. Schrader, T., Peattie, R. A., Bluth, E. I. and Comstock, C. E., 1992, 'A Qualitative Investigation of Turbulence in the Flow Through a Model of an Abdominal Aortic Aneurysm,' Investigative Radiology, Vol. 27, pp. 515-519 https://doi.org/10.1097/00004424-199207000-00008
  3. Peattie, R. A., Schrader, T., Bluth, E. I. and Comstock, C. E., 1994, 'Development of Turbulent in Steady Flow Through Models of Abdominal Aortic Aneurysms,' Journal of Ultrasound in Medicine, Vol. 13, pp. 467-472 https://doi.org/10.7863/jum.1994.13.6.467
  4. Asbury, C. L., Ruberti, J. W., Bluth, E. I. and Peattie, R. A., 1995, 'Experimental Inve stigation of Steady Flow in Rigid Models of Abdominal Aortic Aneurysms,' Annals of Biomedical Engineering, Vol. 23, pp. 29-39 https://doi.org/10.1007/BF02368298
  5. Bluestein, D., Niu, L., Schoephoerster, R. T. and Dewanjee, M. K., 1996, 'Steady Flow in an Aneurysm Model: Correlation Between Fluid Dynamics and Blood Platelet Deposition,' Journal of Biomechanical Engineering, Vol. 118 , pp. 280-286 https://doi.org/10.1115/1.2796008
  6. Yu, S. C. M., 2000, 'Steady and Pulsatile Flow Studies in Abdominal Aortic Aneurysm Models Using Particle Image Velocimetry,' International Journal of Heat and Fluid Flow, Vol. 21, pp. 74-83 https://doi.org/10.1016/S0142-727X(99)00058-2
  7. Oh, S. E. and Rhee, K., 2000 'A Study on the Measurement of Wall Shear Rate in the Abdominal Aortic Aneurysm,' Journal of Biomedical. Engineering Research, Vol. 21, No. 2, pp. 181-187
  8. Shin, S. C., Kim, K. W., Lee, G. H., Moh, J. H. and Kim, D. H., 2001, 'Analysis for the Flow and Wall Shear Stress with a Dilatation of an Abdominal Aortic Aneurysm,' Proceedings of the KSME Spring Annual Conference(E), pp. 560-565
  9. Moh, J.H., 2002, 'Analysis for the Flow and Wall Shear Stress with the Diameter Ratios of an Abdominal Aortic Aneurysm in a Pulsatile Flow,' Journal of Biomedical Engineering Research, Vol. 23, NO. 3, pp. 181-187
  10. Lee, C. S. and Tarbell, J. M., 1997, 'Wall Shear Stress Distribution in an Abdominal Aortic Bifurcation Model: Effects of Vessel Compliance and Phase Angle Between Pressure and Flow Waveforms,' ASME Journal of Biomechanical Engineering, Vol., 119, pp. 333-342 https://doi.org/10.1115/1.2796098
  11. Lou, Z. and Yang, W. J., 1992, 'Biofluid Dynamics of Arterial Bifurcations,' Critical Reviews in Biomedical Engineering, Vol. 19, pp. 455-493
  12. FLUENT User's Guide Volume(Version 5.2)