A Study on the Condition Diagnosis for the Stator Coil of Traction Motor by Transient Surge

과도서지에 의한 견인전동기 고정자 코일의 상태진단 연구

  • 박현준 (한국철도기술연구원 철도전기연구팀) ;
  • 장동욱 (한국철도기술연구원 철도전기연구팀) ;
  • 김길동 (한국철도기술연구원 철도전기연구팀) ;
  • 최종선 (홍익대 전기정보제어공학과) ;
  • 김정수 (홍익대 전기정보제어공학과)
  • Published : 2003.06.01

Abstract

Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the severity of the stresses. The electrical aging by transient surge is very important to traction motor in EMU(electric multiple unit). This paper presents the insulation characteristics of stator coil by transient surge from inverter. There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of leakage current, dielectric loss(tan $\delta$), capacitance, polarization index(PI) and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor in EMU.

전동기 절연열화와 파괴는 전동기에 가해지는 스트레스에 영향을 받는다. 즉 절연물의 수명은 주어지는 스트레스의 심한 정도에 따라서 좌우된다. 전동차용 견인전동기에서도 과도서지에 의한 전기적인 열화를 검토하는 것은 매우 중요한 요소이다. 본 논문에서는 인버터에서 발생되는 과도서지에 의한 고정자 코일의 절연특성을 고찰해 보았다. 전동기의 절연상태, 열화진전도, 열화발생 범위 등을 측정하는 유용한 비파괴시험 방법에는 여러 가지가 이용되고 있다. 누설전류, 유전손실(tan$\delta$), 정전용량, 성극지수(PI), 부분방전 등의 방법들을 통하여 고정자 코일의 절연상태를 분석하였다. 이러한 진단 방법들은 전동차의 견인전동기에 대한 열화상태와 수명예측에 유용한 방법이 될 것으로 여겨진다.

Keywords

References

  1. EPRI, EL-5036 v.16 Handbook to assess the Insulation Condition of Large Rotating Machines I.M.Cullbert;H.Dhirani;G.C.Stone
  2. IEEE Trans.on Energy Conversion v.10 no.4 Analysis of In-Service Aged Stator Bars R.Min;J.P.Nherney;R.Backam;R.Rutherford https://doi.org/10.1109/60.475834
  3. 전기학회기술보고 no.739 -イソバ一タサ一ジの絶緣システムの影響 日本電氣學會
  4. Proceedings of the 1988 Annual Report CEIDP v.2 Investigation on Performances of Insulation Materials for Inverter-FED Traction Motors C.Petrarca;L.Egiziano;V.Tucci;M.Vtelli
  5. 전기적 검출에 의한 고압 유도 전동기 무정전 진단기법 연구 한국전기안전공사
  6. 전동차 전기추진장치의 고장 예방 및 유지관리 자동화시스템 기술개발 한국철도기술연구원
  7. IEEE Trans. on Energy Conversion v.9 no.4 Estimating the Remaining Service Life of Asphalt-Mica Stator Insulation J.E.Timperley;J.R.Michalec https://doi.org/10.1109/60.368340
  8. 차량진단 자동화시스템 분야 한국철도기술연구원
  9. Proceedings of the 1998 Annual Report Conference on Electrical Insulation and Dielectric Phenomena v.2 Dielectric Test Methods for Rotating Machine Stator Insulation Inspection R.Goffeaux;M.Krecke;B.Comte;M.Cottet;B.Fruth
  10. The 8th BEAMA International Electrical Insulation Conference High Voltage Motor Insulation for High Power Adjustable Speed Drives Fed by IGBT-Converter K.Bauer(et al.)
  11. 대한전기학회논문지 v.44 no.8 급준파개폐써지가 유도전동기의 고정자 권선에 미치는 전기적 스트레스 해석 이은웅;김종겸
  12. 전력전자학회논문지 v.6 no.6 PWM 인버터 시스템에서의 전도노이즈 저감을 위한 출력필터 설계에 관한 연구 김이훈;박규현;원충연;김영석;최세완
  13. IEC 60034-18-31 Test procedures for form-wound winding-Thermal evaluation and classification of insulation systems used in machines
  14. IEEE Std.522-1992 Guide for testing turn-to-turn insulation on form-wound stator coils for AC rotating machines