Abstract
The priming discharge characteristic at the reset period in the ADS drive method of PDP was experimentally analyzed in this research. The amount of wall charge accumulated by the discharge and the accumulated time are unrelated to the priming pulse width. The self-erase discharge by excessive wall charge is related to the amount of wall charge by the priming discharge and this is related to space charge generated by the priming discharge. From the experimental result, in the optimized priming condition the plus width is 8$mutextrm{s}$ and the voltage is about 163V. The space charge which helps the self-erase discharge exists during about 16$mutextrm{s}$ immediately after generating the priming discharge. Therefore, it is suitable within 16$mutextrm{s}$ of the priming pluse width for the effective reset process.
본 연구에서는 mP의 ADS 구동방식에서 초기화기간의 프라이밍 방전 특성에 대하여 실험적인 해석을 하였다. 방전에 의해 축적되는 벽전하의 총량과 벽전하가 축적되는 시간은 프라이밍 펄스의 폭과 무관하다. 또한 과잉 벽전하에 의한 자기소거 방전은 프라이밍 방전에 의한 벽전하량과 관계가 있으며 또한 프라이밍 방전에 의해 생성되는 공간전하와도 관계가 있다. 실험결과 프라이밍 펄스 폭은 8[$\mu\textrm{s}$], 전압은 163[V] 정도가 최적이다. 그리고 자기소거방전을 돕는 공간전하는 파라이밍 방전이 발생한 직후로부터 약 16[$\mu\textrm{s}$] 동안 존재한다. 그러므로 효과적인 초기화 과정을 위한 프라이밍 펄스의 폭은 16[$\mu\textrm{s}$] 이내가 적당하다.