Abstract

This paper describes a development of magnetic tomography system using two poles perpendicular magnetic field. In the system, the relative permeabilities of the object are detected by Hall sensors located along with tube circumference. The signals according to the size and position of the object could be separated in case the relative permeability of the object are over 10. Moreover, the size and location of the object could be determined in real time.

Keywords

References

  1. Journal of Communications Technology and Electronics, Vol. 42, No. 41, pp, 469-474, 1997.
  2. Translated from Radiatekhnika i Elektronika, Vol. 42, No. 4, pp. 506-512, 1997
  3. Natterer, F., The Mathematics of Computerized Tomograph, Chichester: Wiley, 1986
  4. Translated under the title Matematicheskie aspekty Komp'yuternoi tomografii, Moscow: Mir, 1990
  5. Barber, D.C. and Brown, B.H., J. Phys. E : Sci, Instrum., vol. 17, no. 9, p. 723, 1984 https://doi.org/10.1088/0022-3735/17/9/002
  6. Powell, H.M., Barber, D.C., Freeston, I.L., Clin. Phys. Physiol. Meas., Vol. 8, suppl. A, p. 109, 1987 https://doi.org/10.1088/0143-0815/8/4A/015
  7. D. L. Atherton, Finite element calculations and computer measurements of magnetic flux leakage patterns for pits', British Journal of NDT, pp. 159-162, May 1988
  8. D. L. Atherton and M.G.Daly, 'Magnetic leakage flux testing with probes: physical principles and restrictions for application', NDT International, vol.20, no. 2, pp. 101-104, April 1987 https://doi.org/10.1016/0308-9126(87)90332-4
  9. B. Brudar, 'Magnetic leakage fields calculated by the method of finite differences', NDT International, vol. 18, no. 6, pp.353-357, December 1985 https://doi.org/10.1016/0308-9126(85)90166-X
  10. D. L. Atherton and D.C.Jiles, 'Effects of stress on the magnetization of steel', IEEE Trans. Magn., vol. 19, no. 5, pp. 2021-2023, September 1983 https://doi.org/10.1109/TMAG.1983.1062784
  11. D. L. Atherton and A.Teitsma, 'Detection of anomalous stress in gas pipelines by magnetometer survey(invited)', J.Appl.Phys. 53(11), pp. 8130-8135, November 1982 https://doi.org/10.1063/1.330316
  12. D. L. Atherton and M. G. Daly, 'Finite Element Calculation of Magnetic Leakage Detector Signals', NDT International, vol. 20, no. 4, pp.235-238, August 1987 https://doi.org/10.1016/0308-9126(87)90247-1
  13. Brown, B.H. et al. 'Cardiac and respiratory related electrical impedance changes in the human thorax', IEEE Trans. Biomed, Eng. 41(8):729-734, 1994 https://doi.org/10.1109/10.310088
  14. Hong, H.D &. M.D. Fox, 'Magnetic back projection imaging of the vascular lumen', IEEE Trans. Biomed, Eng. 42(1): 102-108, 1995 https://doi.org/10.1109/10.362913
  15. Muftuler, L.T. & Y.Z. Ider. 'Measuring AC magnetic field distribution using MRI', In Proc. 18th Int. Conf. IEEE Eng. Med. Med. Biol. Soc. (Amsterdam). 1996 https://doi.org/10.1109/IEMBS.1996.651937