DOI QR코드

DOI QR Code

Simultaneous Determination of Polycyclic Aromatic Hydrocarbons by Synchronous Spectrofluorimetry

형광분광법에 의한 방향족 탄화수소의 동시정량

  • 이상학 (경북대학교 자연과학대학 화학과) ;
  • 손범목 (경북대학교 자연과학대학 화학과)
  • Published : 2003.01.01

Abstract

Synchronous spectrofluorimetry was carried out for the simultaneous determination of various polycyclic aromatic hydrocarbons(PAHs) in aqueous solution by fluorescence spectrometry have been studied. The optimal wavelength interval(${\triangle}{\lambda}$) for synchronous spectra of acenaphthene, anthracene, benzo[a]anthracene, fluorene and pyrene were investigated in the presence of surfactants. The great enhancement of the fluorescence of these PAHs in Triton X-100 was obtained and optimal wavelength was 50 nm. The calibration curves in synthetic mixture solution of 5 PAHs were linear over the range from $1.0{\times}10^{-8}M$ to $1.0{\tiems}10^{-4}M$. Under the optimal experimental conditions, the detection limits were $4.9{\tiems}10^{-9}M$,\;7.0{\times}10^{-9}M,\;4.7{\tiems}10^{-9}M,\;1.6{\tiems}10^{-9}M$ and $3.2{\tiems}10^{-9}M$ for acenaphthene, anthracene, benzo[a]anthracene, fluorene and pyrene, respectively.

Keywords

References

  1. Rodriques, M. A, R C. Tena, and F. J G Montelongo, 1999, determination of polycyclic aromatic hydrocarbons in limpet samples, Chromatographia, 50, 235-238. https://doi.org/10.1007/BF02490657
  2. Kiss, G., Z. V. Puchony, A. Gelencser, Z. Krivacsy, A. Molnar, and J Hlavay, 1998, Survey of concentration of polycyclic aromatic hydrocarbons in lake Balaton by HPLC with fluorescence detection, Chromatographia, 48, 149-153. https://doi.org/10.1007/BF02467532
  3. Dadachs, J., J. M. Bayona, C. Raoux, and J. Albaiges, 1997, Spatial, vertical distribution and budget of polycyclic aromatic hydrocarbons in western mediterranean seawater, Environ. Sci. Technol., 31, 682-688. https://doi.org/10.1021/es960233j
  4. Rodriguez, J. J. S., J. H. Garcia, M. M. B. Surarez, and A B. M. Lazaro, 1993, Analysis of mixtures of polycyclic aromatic hydrocarbons in seawater by synchronous fluorescence spectrometery In organized media, Analyst, l18, 917-921. https://doi.org/10.1039/an9931800917
  5. Pinto, C. G., J. L. P. Pavon, and B. M. Cordero, 1994, Cloud point preconcentration and high-performance liquid chromatographic determination of polycyclic aromatic hydrocarbons with fluorescence detection, Anal. Chem, 66, 874-881. https://doi.org/10.1021/ac00078a019
  6. May, W. E. and S. P. Wasik, 1978, Determination of the aqueous solubility of polynuclear aromatic hydrocarbons by a coupled column liquid chromatographic technique, Anal. Chem, 50, 175-179. https://doi.org/10.1021/ac50023a039
  7. Murayama, M. and P. K. Dasgupta, 1996, Liquid chromatographic determination of nitro-substituted polynuclear aromatic hydrocarbons by sequential electrochemical and fluorescence detection, Anal. Chem, 68, 1226-1232. https://doi.org/10.1021/ac950933r
  8. Later, D. W. and M. L. Lee, 1982, Selective detection of amino acid polycyclic aromatic compounds in solvent refined coal, Anal. Chem., 54, 117-123. https://doi.org/10.1021/ac00238a033
  9. Mcgroddy, S. E. and J. W. Farrington, 1995, Sediment porewater partitioning, of polycyclic aromatic hydrocarbons in three cores from boston harbor, massachusetts, Environ. Sci. TechnoL, 29, 1542-1550. https://doi.org/10.1021/es00006a016
  10. Dickhut, R. M. and K. E. Gustafson, 1995, Atmospheric washout of polycyclic aromatic hydrocarbons in the southern chesapeake bay region, Environ. Sci. Technol, 29, 1518-1525. https://doi.org/10.1021/es00006a013
  11. Wise, S. A., M. M. Schantz, B. A. Benner, Jr., M. J. Hay, and S. B. Schiller, 1995, Certification of polycyclic aromatic hydrocarbons in a marine sediment standard reference material, Anal. Chem., 67, 1171-1178. https://doi.org/10.1021/ac00103a006
  12. Patil, S. R. and S. B. Patwari, 1999, Red shift in fluorescence of naphthalene doped by anthracene and perylene, Journal of Luminescence, 82, 115-119. https://doi.org/10.1016/S0022-2313(99)00035-6
  13. Ayala, J. H., A. M. Afonso, and V. G. Diaz, 1998, Selective analysis of fluorene by quenched fluorescence in cetylpyridinium bromide micelles, Microchemical Journal, 60, 101-109. https://doi.org/10.1006/mchj.1998.1637
  14. Schwarz, F. P. and S. P. Wasik, 1976, Fluorescence measurements of benzene, naphthalene, anthracene, pyrene, fluoranthene and benzene [eJpyrene in water, Anal. Chem., 48, 534-528. https://doi.org/10.1021/ac60371a702
  15. Cirovic, D. A., R. G. Brereton, P. T. Walsh, J. A Ellwood, and E. Scobbie, 1996, Application of partial least squares calibration to measurements of polycyclic aromatic hydrocarbons in coal tar pitch volatiles, Analyst, 121, 575-580. https://doi.org/10.1039/an9962100575
  16. Green, G. L. and T. C. O'Haver, 1974, Derivative luminescence spectrometry, Anal. Chem., 46, 2191-2196. https://doi.org/10.1021/ac60350a043
  17. Latz, H. W, A H. Ullmar, and J. D. Winefordener, 1978, Limitation of synchronous luminescence spectrometry in multicomponent analysis, Anal. Chem., 50 656-657. https://doi.org/10.1021/ac50026a031
  18. Khakhel', O. A and V. E. Krykunova, 1999, Determination of dimer concentration of chromophores by the method of fluorescence synchronous scanning, Journal of Luminescence, 81, 79-84. https://doi.org/10.1016/S0022-2313(98)00049-0
  19. Chou, J. X. Qu, T. Lu, S. Dong, and Y. Wu, 1995, The effect of solution pH on synchronous fluorescence spectra of cytochrome c solution, Microchemical Journal, 52, 159-165. https://doi.org/10.1006/mchj.1995.1080
  20. Inman, E. L. Jr. and J. D. Winefordner, 1982, Constant energy synchronous fluorescence for analysis of polynuclear aromatic hydrocarbon mixture, Anal. Chem., 54, 2018-2022. https://doi.org/10.1021/ac00249a025
  21. Rubio, S., A. G. Hens, and M. Valcarcel, 1985, Analysis of binary and ternary mixtures of titanium, zirconium and hafnium by derivative synchronous fluorescence spectrometry, Anal. Chem., 57, 1101-1106. https://doi.org/10.1021/ac00283a031