Design and Test of Vacuum Rotary Arc Gap Switch

Vacuum Rotary Arc Gap Switch의 설계 및 시험

  • Published : 2003.01.01

Abstract

Design and test results of a VRAG(Vacuum Rotary Arc Gap) switch were presented. To control the damage of electrodes caused by the vacuum arc, Lorentz's force by the radial magnetic field between spiral electrodes was used to rotate the vacuum uc. VRAG switch electrodes were made of the material of CuCr and OFHC. Gap distance between two spiral type electrodes for the rotation of the arc discharge is 8, 10, 12mm. In the cathode, one trigger electrode was inserted into each spiral wing. Normal operation of the VRAG switch was confirmed with 10.6[$mutextrm{s}$]of trigger delay and 2~3[$mutextrm{s}$] of the jitter time. The speed of the vacuum arc was measured to be 0.6 ~ 1[km/s] by a motion analyzer.

Keywords

References

  1. S. T. Pai & Qi Zhang, Introduction to high power pulse technology, Advanced Series in Electrical and Computer Engineering, Vol 10
  2. Gerhard Schaefer and M. Kristiansen, Gas Discharge Closing Switches, Prenum press, 1990
  3. 임근희, 이홍식, 강동필, Rotary Arc Gap (5kV, 100kA) 투입 스위치 개발, 과학기술부 특정연구개발사업 연구보고서, 97-NZ-01-01-A-31, 2000
  4. Farrall, G.A., Current Zero Phenomena, Chap 6, in; 'Vacuum Arcs', J.M. Lafferty, ed., Wiley-Interscience, New York, 1980
  5. A. J. Green and C. Christopoulos 'Plasma buildup and breakdown delay in a triggered vacuum gap' IEEE Transactions on plasma science, Vol. PS-7, No.2, pp 111 - 115, June 1979
  6. J. M. Lafferty, 'Triggered Vacuum Gaps', Proceeding of The IEEE Vol. 54, No. I, pp 23 - 32, January 1966
  7. S Kamakshaiah and R S N Rau 'Low-voltage and high-current delay characteristics of a simple triggered vacuum gap', J. Phys, D : Appl, Phys., Vol. 8, pp 1017 - 1022, 1975 https://doi.org/10.1088/0022-3727/10/7/008
  8. G. N. Aretov, V. I. Vasil'ev, M. I. Pergament, and S. S. Tserevitinov, 'Delay characteristics of Vacuum Disc Switchs', Soviet Physics- Technical Physics, Vol. 12, No.1, pp 90 - 96 July, 1967