DOI QR코드

DOI QR Code

Determination of Ag(Ⅰ) Ion at a Modified Carbon Paste Electrode Containing N,N'-Diphenyl Oxamide

  • Published : 2003.07.20

Abstract

New approach for the determination of Ag(I) ion was performed by using a carbon paste electrode (CPE) containing N,N'-Diphenyl oxamide (DPO) with anodic stripping voltammetry. The CMEs have been prepared by making carbon paste mixtures containing an appropriate amount of DPO salt coated onto graphite particles to analyze trace metal ions via complexation followed by stripping voltammetry. Various experimental parameters affecting the response, such as pH, deposition time, temperature, and electrode composition, were carefully optimized. Using differential pulse anodic stripping voltammetry, the logarithmic linear response range for the Ag(I) ion was 1.0 × $10^{-7}$ - 5.0 × $10^{-9}$ M at the deposition time of 10 min, with the detection limit was 7.0 × $10^{-10}$ M. The detection limit adopted from anodic stripping differential pulse voltammetry was 7.0 × $10^{-10}$ M for silver and the relative standard deviation was ± 3.2% at a 5.0 × $10^{-8}$ M of Ag(I) ion (n = 7). The proposed electrode shows a very good selectivity for Ag(I) in a standard solution containing several metals at optimized conditions.

Keywords

References

  1. Murry, R. W. Electroanalytical Chemistry; Bard, A. J., Ed.;Marcel Dekker: New York, 1984; Vol. 13, pp 191-368.
  2. Abruna, H. D. Coord. Chem. Rev. 1988, 86, 135. https://doi.org/10.1016/0010-8545(88)85013-6
  3. Widrig, C. A.; Porter, M. D.; Ryan, M. D.; Strein, T. G.; Ewing, A.G. Anal. Chem. 1990, 62, 1R. https://doi.org/10.1021/ac00211a009
  4. Ryan, M. D.; Chambers, J. Q. Anal. Chem. 1992, 64, 79R. https://doi.org/10.1021/ac00036a005
  5. Murray, R. W.; Ewing, A. G.; Durst, R. A. Anal. Chem. 1987, 59,379A. https://doi.org/10.1021/ac00132a001
  6. Imisides, M. D.; Jhon, R.; Riley, P. J.; Wallace, G. G.Electroanalysis 1991, 3, 879. https://doi.org/10.1002/elan.1140030903
  7. Won, M. S.; Bae, Y. J.; Lee, S. S.; Shim, Y. B. Electroanalysis2001, 12, 13.
  8. Kong, Y. T.; Choi, G. H.; Won, M. S.; Shim, Y. B. ChemistryLetters 2002, 1, 54.
  9. Wang, J. Stripping Analysis: Instumentation and Application;Verlag Chemie: Deerfield Beach, FL, 1985.
  10. Treatise on Analytical Chemistry; Kolthoff, M. H., Eiving, P. J.,Eds.; Interscience: New York, 1966; Part II, Vol. 5.
  11. Renner, H. Ulmanns Encyclopedia of Industrial Chemistry, 5thed.; VCH: New York, 1993; vol. A24.
  12. Ambient Water Quality Criteria for Silver; EPA 4405-80-071,Office of Water Regulation, Washington, DC, 1980.
  13. Metals and Their Compounds in the Environment; Meian, E., Ed.;VCH: New York, 1991.
  14. Cheek, G. T.; Nelson, R. F. Anal. Lett. 1978, A11, 393.
  15. Gao, Z.; Xu, Y.; Wang, G.; Zhao, Z. Anal. Chim. Acta 1990, 229,213. https://doi.org/10.1016/S0003-2670(00)85131-4
  16. Wang, J.; Naser, N.; Darnall, D.; Garder-Toresdey, J. Electroanalysis1992, 4, 71. https://doi.org/10.1002/elan.1140040114
  17. Turyan, I.; Mandler, D. Electroanalysis 1994, 6, 838. https://doi.org/10.1002/elan.1140061005
  18. Tanaka, S.; Yoshifa, H. Talanta 1989, 36, 1044. https://doi.org/10.1016/0039-9140(89)80191-2
  19. Yeom, J. S.; Won, M. S.; Choi, S. N.; Shim, Y. B. Bull. KoreanChem. Soc. 1990, 11, 200.
  20. Kim, S. H.; Won, M. S.; Shim, Y. B. Bull. Korean Chem. Soc.1994, 38, 734.
  21. Won, M. S.; Moon, D. H.; Shim, Y. B. Electroanalysis 1995, 7,3421.
  22. Lee, J. W.; Park, D. S.; Shim, Y. B.; Park, S. M. J. Electrochem.Soc. 1992, 139, 3507. https://doi.org/10.1149/1.2069107
  23. Park, D. S.; Shim, Y. B.; Park, S. M. Electroanalysis 1996, 8, 44. https://doi.org/10.1002/elan.1140080110
  24. Takeshima, T.; Yokoyama, M.; Iamaoto, T.; Akano, M.; Asaka, H.J. Org. Chem. 1996, 34, 730. https://doi.org/10.1021/jo01255a054
  25. Prabhu, S. V.; Baldwin, R. P. Anal. Chem. 1987, 59, 1074. https://doi.org/10.1021/ac00135a002

Cited by

  1. Anodic stripping voltammetric determination of silver ion at a carbon paste electrode modified with carbon nanotubes vol.173, pp.1-2, 2011, https://doi.org/10.1007/s00604-010-0528-5
  2. Sulfhydryl Cotton Enrichment Separation-Determination of Silver in Geological Samples by ICP-MS vol.32, pp.10, 2011, https://doi.org/10.5012/bkcs.2011.32.10.3561
  3. Anodic stripping voltammetric determination of silver(I) in water using a 4-tert-butyl-1(ethoxycarbonylmethoxy)thiacalix[4]arene modified glassy carbon electrode vol.66, pp.1, 2011, https://doi.org/10.1134/S1061934811010047
  4. Fabrication of a new multi-walled carbon nanotube paste electrode for stripping voltammetric determination of Ag(i) vol.137, pp.10, 2012, https://doi.org/10.1039/c2an16004h
  5. Water-Free Neodymium 2,6-Naphthalenedicarboxylates Coordination Complexes and Their Application as Catalysts for Isoprene Polymerization vol.51, pp.1, 2012, https://doi.org/10.1021/ic2019346
  6. Anodic stripping voltammetry of silver(I) using a carbon paste electrode modified with multi-walled carbon nanotubes vol.180, pp.5-6, 2013, https://doi.org/10.1007/s00604-012-0935-x
  7. Application of poly 3-methylthiophene for removal of silver ion from aqueous solutions vol.113, pp.4, 2009, https://doi.org/10.1002/app.30239
  8. Differential pulse anodic stripping voltammetry of silver(I) using p-isopropylcalix[6]arene modified carbon paste electrode vol.141, pp.3, 2010, https://doi.org/10.1007/s00706-010-0258-8
  9. 도파민으로 수식된 SAMs 전극에서 NADH의 전기촉매에 의한 산화 vol.48, pp.2, 2003, https://doi.org/10.5012/jkcs.2004.48.2.151
  10. Pt-Nanoparticle Incorporated Carbon Paste Electrode for the Determination of Cu(II) Ion by Anodic Stripping Voltammetry vol.19, pp.11, 2003, https://doi.org/10.1002/elan.200703835
  11. Langmuir–Blodgett film of p-tert-butylthiacalix[4]arene modified glassy carbon electrode as voltammetric sensor for the determination of Ag+ vol.630, pp.1, 2003, https://doi.org/10.1016/j.jelechem.2009.02.014
  12. Differential Pulse Anodic Stripping Voltammetric Simultaneous Determination of Copper(II) and Silver(I) with Bis(2-hydroxyacetophenone) Butane-2,3-dihydrazone Modified Carbon Paste Electrodes vol.22, pp.19, 2010, https://doi.org/10.1002/elan.201000190
  13. Fabrication of an electrochemical sensor based on metal-organic framework ZIF-8 for quantitation of silver ions: optimizing experimental conditions using central composite design (CCD) vol.12, pp.23, 2003, https://doi.org/10.1039/d0ay00843e