In the present investigation the experimental and theoretical flexural and compressive behavior of short tubular steel columns filled with plain concrete and fiber-reinforced concrete (FRC) was examined. For a given length of the members, the effects of different geometry and dimensions of the transverse cross-section (square and circular) were investigated. Constituent materials were characterized through direct tensile tests on steel coupons and through compressive and split tension tests on concrete cylinders. Load-axial shortening and load-deflection curves were recorded for unfilled and composite members. Finally, simplified expressions for the calculus of the load-deflection curves based on the cross-section analysis were given and the ultimate load of short columns was predicted.

Keywords

References

  1. Beedle, L.S. et al. (Editors), (1989), "Stability of metal structures", A world view. 2nd ed. Structural Stability Research Council, Bethlehem, Pa.
  2. Campione, G., Mindess, S., Scibilia, N. and Zingone, G. (1999), "Compressive behaviour of circular steel columns filled with fiber-reinforced concrete: experimental investigation and comparison with EC4 code", Costruzioni Metalliche 5, 41-48.
  3. Campione, G., Mindess, S., Scibilia, N. and Zingone, G. (2000), "Strength of hollow circular steel sections filled with fibre-reinforced concrete", Can. J. Civ. Eng. 27, 364-372. https://doi.org/10.1139/l99-079
  4. Campione, G., La Mendola, L., Scibilia N., Sanpaolesi L. and Zingone, G. (2001), "Behavior of fiber-reinforced concrete filled tubular columns in compression", Material and Structures, 35, 332-337.
  5. CSA (1994), "Limit states design of steel structures. Standard CSA S16.1-94", Canadian Standards Association, Rexdale, Ont.
  6. Cosenza, E. and Pecce E.M. (2000), "Le colonne composte acciaio-calcestruzzo: analisi sperimentali, modelli di calcolo, indicazioni normative", Costruzioni Metalliche, 2, 49-60 (only available in Italian).
  7. Cusson, D. and Paultre, P. (1995), "Stress-strain model for confined high-strength concrete", J. Struct. Engng. ASCE, 121 3, 468-477. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:3(468)
  8. Eurocode 4 (1994), "Design of composite steel and concrete Structures", European Committee for Standardization (CEN), ENV 1994-1-1.
  9. Felicetti, R. and Gambarova, P.G. (1998), "Effects of high temperature on the residual compressive strength of high-strength siliceous concretes", ACI Materials Journal, 95 4, 395-406.
  10. Han L., Zhao, X. and Tao, Z. (2001)," Tests and mechanics model for concrete-filled SHS stub columns, columns and beam-columns", Steel & Composite Structures, 1 1, 51-74 https://doi.org/10.1296/SCS2001.01.01.04
  11. Issa, M.A. and Tobaa, H. (1994), "Strength and ductility enhancement in high-strength confined concrete", Magazine of Concrete Research 46(168), 177-189. https://doi.org/10.1680/macr.1994.46.168.177
  12. Johansson, M. and Kent, G. (2001), "Structural bebavior of slender circular steel-concrete composite columns under various means of load application", Steel & Composite Structures, 1(4), 393-410. https://doi.org/10.12989/scs.2001.1.4.393
  13. Manual of Steel Construction, "Load and resistance factor design (LRFD) 1994", 2nd Ed., Am. Inst. of Steel Constr. Chicago, I11.
  14. Prion, H., G.L. and Boheme, J. (1993), "Beam-column behaviour of steel tubes filled with high strength concrete", Can. J. Civ. Eng., 21, 207-218.
  15. Shams, M. and Saadeghvaziri, M.A. (1997), "State of the art concrete-filled steel tubular columns", ACI Struct. Journal, 94(5), 558-571.
  16. Sohal, I.S. and Chen, W.F. (1987), "Local buckling and sectional behavior of fabricated tubes", J. Struct. Eng., ASCE 113(4), 519-533. https://doi.org/10.1061/(ASCE)0733-9445(1987)113:3(519)
  17. Sohal, I.S. and Chen W.F. (1988), "Local and post-buckling behavior of tubular beam-columns", J. Struct. Eng., ASCE 114(5), 1073-1089. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:5(1073)
  18. Schneider, S.P. (1998), "Axially loaded concrete-filled steel tubes", J. Struct. Eng. ASCE, 124(10), 1125-1138. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:10(1125)
  19. Uy, B. (2000), "Strength of concrete filled steel box columns incorporating local buckling", J. Struct. Eng. ASCE, 126(3), 341-352. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:3(341)
  20. Kodur, V.K.R. and Lie, T.T. (1995), "Fire resistance of hollow steel columns filled with steel fibre-reinforced concrete", Fiber-reinforced Concrete. Modern Developments, The University of British Columbia, Vancouver, Canada, Ed. N. Banthia, S. Mindess, 289-302.

Cited by

  1. Axial strength of circular concrete-filled steel tube columns — DOE approach vol.66, pp.10, 2010, https://doi.org/10.1016/j.jcsr.2010.04.006
  2. Experimental behaviour of concrete-filled stiffened thin-walled steel tubular columns vol.45, pp.5, 2007, https://doi.org/10.1016/j.tws.2007.04.003
  3. Experimental study on the behavior of CFT stub columns filled with PCC subject to concentric compressive loads vol.5, pp.1, 2005, https://doi.org/10.12989/scs.2005.5.1.017
  4. Capacity and the moment-curvature relationship of high-strength concrete filled steel tube columns under eccentric loads vol.7, pp.2, 2007, https://doi.org/10.12989/scs.2007.7.2.135
  5. AN INVESTIGATION INTO WORKING BEHAVIOR CHARACTERISTICS OF PARABOLIC CFST ARCHES APPLYING STRUCTURAL STRESSING STATE THEORY vol.25, pp.3, 2002, https://doi.org/10.3846/jcem.2019.8102