References
- Beedle, L.S. et al. (Editors), (1989), "Stability of metal structures", A world view. 2nd ed. Structural Stability Research Council, Bethlehem, Pa.
- Campione, G., Mindess, S., Scibilia, N. and Zingone, G. (1999), "Compressive behaviour of circular steel columns filled with fiber-reinforced concrete: experimental investigation and comparison with EC4 code", Costruzioni Metalliche 5, 41-48.
- Campione, G., Mindess, S., Scibilia, N. and Zingone, G. (2000), "Strength of hollow circular steel sections filled with fibre-reinforced concrete", Can. J. Civ. Eng. 27, 364-372. https://doi.org/10.1139/l99-079
- Campione, G., La Mendola, L., Scibilia N., Sanpaolesi L. and Zingone, G. (2001), "Behavior of fiber-reinforced concrete filled tubular columns in compression", Material and Structures, 35, 332-337.
- CSA (1994), "Limit states design of steel structures. Standard CSA S16.1-94", Canadian Standards Association, Rexdale, Ont.
- Cosenza, E. and Pecce E.M. (2000), "Le colonne composte acciaio-calcestruzzo: analisi sperimentali, modelli di calcolo, indicazioni normative", Costruzioni Metalliche, 2, 49-60 (only available in Italian).
- Cusson, D. and Paultre, P. (1995), "Stress-strain model for confined high-strength concrete", J. Struct. Engng. ASCE, 121 3, 468-477. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:3(468)
- Eurocode 4 (1994), "Design of composite steel and concrete Structures", European Committee for Standardization (CEN), ENV 1994-1-1.
- Felicetti, R. and Gambarova, P.G. (1998), "Effects of high temperature on the residual compressive strength of high-strength siliceous concretes", ACI Materials Journal, 95 4, 395-406.
- Han L., Zhao, X. and Tao, Z. (2001)," Tests and mechanics model for concrete-filled SHS stub columns, columns and beam-columns", Steel & Composite Structures, 1 1, 51-74 https://doi.org/10.1296/SCS2001.01.01.04
- Issa, M.A. and Tobaa, H. (1994), "Strength and ductility enhancement in high-strength confined concrete", Magazine of Concrete Research 46(168), 177-189. https://doi.org/10.1680/macr.1994.46.168.177
- Johansson, M. and Kent, G. (2001), "Structural bebavior of slender circular steel-concrete composite columns under various means of load application", Steel & Composite Structures, 1(4), 393-410. https://doi.org/10.12989/scs.2001.1.4.393
- Manual of Steel Construction, "Load and resistance factor design (LRFD) 1994", 2nd Ed., Am. Inst. of Steel Constr. Chicago, I11.
- Prion, H., G.L. and Boheme, J. (1993), "Beam-column behaviour of steel tubes filled with high strength concrete", Can. J. Civ. Eng., 21, 207-218.
- Shams, M. and Saadeghvaziri, M.A. (1997), "State of the art concrete-filled steel tubular columns", ACI Struct. Journal, 94(5), 558-571.
- Sohal, I.S. and Chen, W.F. (1987), "Local buckling and sectional behavior of fabricated tubes", J. Struct. Eng., ASCE 113(4), 519-533. https://doi.org/10.1061/(ASCE)0733-9445(1987)113:3(519)
- Sohal, I.S. and Chen W.F. (1988), "Local and post-buckling behavior of tubular beam-columns", J. Struct. Eng., ASCE 114(5), 1073-1089. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:5(1073)
- Schneider, S.P. (1998), "Axially loaded concrete-filled steel tubes", J. Struct. Eng. ASCE, 124(10), 1125-1138. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:10(1125)
- Uy, B. (2000), "Strength of concrete filled steel box columns incorporating local buckling", J. Struct. Eng. ASCE, 126(3), 341-352. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:3(341)
- Kodur, V.K.R. and Lie, T.T. (1995), "Fire resistance of hollow steel columns filled with steel fibre-reinforced concrete", Fiber-reinforced Concrete. Modern Developments, The University of British Columbia, Vancouver, Canada, Ed. N. Banthia, S. Mindess, 289-302.
Cited by
- Axial strength of circular concrete-filled steel tube columns — DOE approach vol.66, pp.10, 2010, https://doi.org/10.1016/j.jcsr.2010.04.006
- Experimental behaviour of concrete-filled stiffened thin-walled steel tubular columns vol.45, pp.5, 2007, https://doi.org/10.1016/j.tws.2007.04.003
- Experimental study on the behavior of CFT stub columns filled with PCC subject to concentric compressive loads vol.5, pp.1, 2005, https://doi.org/10.12989/scs.2005.5.1.017
- Capacity and the moment-curvature relationship of high-strength concrete filled steel tube columns under eccentric loads vol.7, pp.2, 2007, https://doi.org/10.12989/scs.2007.7.2.135
- AN INVESTIGATION INTO WORKING BEHAVIOR CHARACTERISTICS OF PARABOLIC CFST ARCHES APPLYING STRUCTURAL STRESSING STATE THEORY vol.25, pp.3, 2002, https://doi.org/10.3846/jcem.2019.8102