An Evaluation of the Uncertainty of Pressure Measurement Systems

압력 측정 시스템의 불확도 평가

  • Published : 2002.05.01

Abstract

Uncertainty components and evaluation of the system of pressure measurement are presented in this paper. Since early in 1980s, measurement uncertainty is getting more important due to ISO/IEC 17025, which is established for international test and calibration laboratories. Up to now it is true that accuracy, precision, error and etc. have been commonly used in industry to define the amount of error to the products and equipment, but these terms ought to be united into uncertainity in the future. This paper describes how to indicate measurement uncertainty and types of measurement errors, and then shows the evaluation result of measurement system using piezoelectric pressure transducers.

Keywords

References

  1. KASTO 교육사업부 '국가교정제도 및 국가교정 기관 인정절' 한국계량측정협회, KASTO-EDA-01, 2000. 11
  2. Barry N. Taylor and Chris E. Kuyatt, 'Guide Lines for Evaluation and Expressing the Uncertainty of NIST Measurement Result', NIST Techniqcal Note 1297, pp.1-25, 1992.
  3. Edward E.Herceg, 'Handbook of Measurement and Control', Schacvitz Engineering Pennsauken, N. J. pp.3-1/3,16, pp.14-1/14-14
  4. 최주호, 홍성수, 유준, '추정시스템의 정확도 평가와 공인화 절차’ 한국군사과학기술학회지 제2권 (통권 제3호), 1999. 12
  5. Quantifying Uncertainty in Analytical Measurement ISO Reference 17025, 2000. 5
  6. Guide to the Expression of Uncertainty in Measurement ISO Reference 2000. 4