References
- Weine F, Kelly R, Lio P. The effect of preparation procedures on the original canal shape and on apical foramen shape. J Endodon 1975;1:255-62 https://doi.org/10.1016/S0099-2399(75)80037-9
- Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974;18:269-96
- Weine F. Endodontic therapy St. Louis: CV Mosby. 1989:277
- Walton R. Current concepts of canal preparation. Dent Clin North Am 1992;32:309-326
- Morgan LA, Montgomery S. An evaluation of the crown-down pressureless technique. J Endodon 1984;10:491-8 https://doi.org/10.1016/S0099-2399(84)80207-1
- Goerig A, Michelich R, Schultz H. Instrumentation of root canals in molars using the step-down technique. J Endodon 1982;8:550-4 https://doi.org/10.1016/S0099-2399(82)80015-0
- Roane J. Sabala C. Duncanson M. The 'balanced force' concept for instrumentation of curved canals. J Endodon 1985;11 203-11 https://doi.org/10.1016/S0099-2399(85)80061-3
- Chenail BL. Teplitsky PE. Endosonics in curved root canals. J Endodon 1985; 11:369-74 https://doi.org/10.1016/S0099-2399(85)80022-4
- Walsh C, EIDeeb ME. Messee HH. Effect of varying ultrasonic power on instrumentation time and prepared canal space. J Endodon 1987;13:133-8
- Walia H, Brantley WA, Gerstein H, An investigation of the bending and torsional properties of Nitinol root canal files. J Endodon 1988;14:346-51
- Esposito PT, Cunningham CJ. A comparison of canal preparation with Nickel-Titanium and Stainless steel instruments. J Endodon 1995;21:173-6 https://doi.org/10.1016/S0099-2399(06)80560-1
- 백승호, 만곡근관에서 Engine-driven NiTi file, 초음파기구, stainless steel file을 이용한 근관형성 후 근관형태 변화에 관한 연구, 대한치과협회지 1995;34:5:363-371
- 박한수 등, ProFile을 이용한 만곡근관 형성시 근관형태에 관한 연구, 대한치과보존학회지, 24:633-637
- Hata G, Uemura M, Toda T. Kato AS, Irnura, A comparison of shaping ability using ProFile, GT file, and Flex-R endodontic instruments in simulated canals. J Endodon. 25:4:299, 1999
- Bramante CM, Berbert A, Borges RP: A Methdology for evaluation of root canal instrumentation. J Endodon 13;243-45. 1987 https://doi.org/10.1016/S0099-2399(87)80099-7
- Calhoun G, Mongomery S. The effects of four instrumentation technique on root canal shape. J Endodon. 14: 273-277, 1988 https://doi.org/10.1016/S0099-2399(88)80025-6
- Lee SJ, Shin YG, Hwang HK. Transportation of curved canal after canal enlargement according to filing instruments. J KACD 24:503-510, 1999
- Haga CS, Microscope measurements of root canal preparations folowing instrumentation, J Br Endo Soc 2:41-46, 1968 https://doi.org/10.1111/j.1365-2591.1968.tb01209.x
- Walton RE. Histologic evaluation of different methods of enlarging the pulp canal space, J Endodon 10:304-310, 1976
- Mizrahi SJ, Yucker JW, Seltzer S: A scanning electron microscopic study of the efficacy of various endodontic instruments. J Endodon 1:324-33, 1975 https://doi.org/10.1016/S0099-2399(75)80012-4
- Bolanos OR, Jensen JR. Scanning electron microscope comparison of the efficacy of various methods of root cnal preparation. J Endodon 6:815-821, 1980 https://doi.org/10.1016/S0099-2399(80)80034-3
- Tachibana H, Matsumoto K : Applicability of x-ray computerized tomography in endodontics. Endod Dent Traumatol 6:16-20, 1990 https://doi.org/10.1111/j.1600-9657.1990.tb00381.x
- Gambill JM, Alder M, Rio CE Comparioson of NickelTitanium and stainless steel hand-file instrumentation using computed tomography J Endodon 22:369-375, 1996 https://doi.org/10.1016/S0099-2399(96)80221-4
- Buchanan LS. The shape of things to come. Dentistry today., 13 1994
- Tucker DM. Wenckus CS, Bentkover SK: Canal wall planning by engine-driven Nickel-Titanium instruments, compared with stainless steel hand instrumentation. J Endodon 23:170-173, 1997 https://doi.org/10.1016/S0099-2399(97)80269-5
- Luiten DJ, Morgan LA, Baumgartner JC. A comparison of four instrumentation techniques on apical canal transportation. J Endodon 21:26-32, 1995 https://doi.org/10.1016/S0099-2399(06)80553-4
- 이지현, 조용범 수종의 근관형성 방법이 근관형태에 미치는 영향, 대한치과보존협회지 24:337-345, 1999
- Kosa DA, Marshall G, Baumgartner JC An analysis of canal centring using mechanical instrumentation techniques, J Endodon 25:441-445, 1999 https://doi.org/10.1016/S0099-2399(99)80275-1
- Lim KA, Yoon SH A comparision of stainless steel K-file, Profile.04, and Quantec LX instruments to shape curved root canals in vitro, 대한치과보존학회지 25:133-140, 2000
- Glosson CR, Haller RH. Dove SB, Rio CE. A comparison of root canal preparations using NiTi hand, NiTi engine-driven, and K-Flex endodontic instruments. J Endodon 1005;21:146-51 https://doi.org/10.1016/S0099-2399(06)80441-3
- Baumgartner JC, Martin H, Sabala CL, Strittmatter EJ, Wildey WL, Quigley NC. Histomorphic comparison of canals prepared by four techniques. J Endodon 1992; 17:530-4
- Bou Dagher FE, Yared GM. Comparison of three files to prepare curved root canals. J Endodon 1995;21:264-5 https://doi.org/10.1016/S0099-2399(06)80994-5
Cited by
- A comparative study on the canal configuration after shaping by ProFile, ProTaper™ and K-Flexofile in simulated canals with different angles of curvature vol.30, pp.4, 2005, https://doi.org/10.5395/JKACD.2005.30.4.294
- Comparison of shaping ability of rotary Ni-Ti file systems used by undergraduates vol.31, pp.1, 2006, https://doi.org/10.5395/JKACD.2006.31.1.001
- in simulated canals with different curvatures vol.32, pp.2, 2007, https://doi.org/10.5395/JKACD.2007.32.2.087
- Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography vol.36, pp.3, 2011, https://doi.org/10.5395/JKACD.2011.36.3.231