Measurement and Analysis of Magnetic Fields and Induced Voltages Caused by Home Appliances

가정용 전기기구에서 발생하는 자장과 유도전압의 측정과 분석

  • Published : 2002.11.01

Abstract

This paper deals with the measurement and analysis of the induced voltages and magnetic fields caused by the operation of home appliances. The induced voltage and magnetic field measurement circuit used in this work consists of the induction coil, the operational preamplifier and the active integrator. Television set and monitors for personal computer cause strong magnetic fields rich in harmonics and high induced voltages by using the switching power suppliers. The strong magnetic field intensity and high induced voltage were created by 14" television set, and their values are 2.1 [$\mu$Tp-p]and 140 [mVp-p]at the distance of 0.4 [m], respectively. However, the induced voltage per unit magnetic field intensity was created by 17" monitor for personal computer and the measured data was approximately 560[mV/$\mu$T]at the same distance. distance.

논문은 가전기구의 사용으로 발생하는 유도전압 및 자장의 측정과 분석에 대한 것으로 본 실험에 사용한 유도전압과 자장 측정회로는 유도코일, 선행증폭기, 그리고 능동적분기로 구성하였다. TV와 퍼스널 컴퓨터용 모니터는 스위칭소자로 동작하는 전원장치를 사용하므로 고조파 성분을 많이 포함하는 강한 자장과 유도전압을 발생시켰다. 14"TV 주변에서 큰 자장과 높은 유도전압이 나타났고, 그 값은 측정거리 0.4 [m]에서 각각 2.1 [$\mu$Tp-p]와 140[mVp-p]이었다. 그러나 동일한 측정거리에서 단위 자장의 세기에 대한 유도전압은 17"모니터에서 약560 [mV/$\mu$T]로 가장 크게 나타났다.장 크게 나타났다.

Keywords

References

  1. William F. Horton, Saul Goldberg, “Power Frequency Magnetic Fields and Public Health”, CRC Press, pp. 5-85, 131-178, 1995.
  2. 이복희, 이승칠, 안창환, 길형준, 전덕규, 길경석, “345[kV] 송전철탑 주변에서 전장과 자장의 측정과 분석”, 조명.전기설비학회 논문지, Vol. 12, No. 3, pp. 14-21, 1998
  3. W. Kohler, “Measurement and Calculation of Low Frequency Electric and Magnetic Fields”, 9th ISH, 8338- 1-4, 1995.
  4. R. P. Corcoran, “Extremely Low Frequency Exposure Limits Relative to Military Electrical/Electronic System Environments”, IEEE Int. EMC Symposium, pp. 62-67, 1992. https://doi.org/10.1109/ISEMC.1992.626049
  5. “IEEE Standard Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power Lines”, ANSI/IEEE Std. 644-1987, pp. 17-21, 1992.
  6. E. Zemman, S. Frei, et al., “Investigations of Exposition to Low Frequency Magnetic Fields”, 9th ISH, 8347-1-4, 1995.
  7. J.P. Hauser, "A 20 Hz to 200 kHz Magnetic Flux Probe for EMI Surveys", IEEE Trans., Vol. EMC-32, No. 1, pp. 67-69, 1990. https://doi.org/10.1109/15.45242
  8. S. A. Macintyre, “A Portable Low Noise Low Frequency Three-axis Search Coil Magnetometer”, IEEE Trans. MAG, Vol. MAG-16, No. 5, pp. 761-763, 1980. https://doi.org/10.1109/TMAG.1980.1060818
  9. 이복희, 이정기, “345/154kV 초고압 송변전설비 주변에서 의 자장의 측정과 분석 ”, 대한전기학회 논문지, Vol. 46, pp. 414-420, 1997.
  10. AC fields working group of the IEEE, “An Evaluation of Instrumentation Used to Measure AC Power System Magnetic Fields”, IEEE Trans. PD, Vol. 6, No. 1, 1991. https://doi.org/10.1109/61.103761
  11. TCO′99-Mandatory and Recommended Requirements for CRT-type Visual Display Units(VDUs) concerning:", pp11-13, 1999.