Abstract

In this paper harmonic diagnose tool is described for electric evaluate the power quality at industrial power systems is described both simulation and experimental testing during various operation conditions. PTW (Power Tools for Windows) and harmonic measuring instrument are organized around personal computer and/or instrumentation study environments interconnected via RS-232. Unknown zero sequence impedance data of cable is calculated by the modified T&D and BICC method. IEEE standard is also used to estimate the transformer input data. the proposed system provides a flexible and effective environment to diagnose the power quality at industrial distribution systems by utilizing simulations and actual field data.

본 연구는 산업용 전력계통에서의 전기 품질을 개선하기 위한 고조파 진단 툴의 개발에 대한 것이다. 이 시스템은 계통의 다양한 운전상태에서 시뮬레이션과 계측을 통한 전기품질 분석에 적합하도록 구성하였다. 시뮬레이션은 PTW(Power Tools for Windows)를 이용하였고, 고조파 측정에는 Dranetz사의 PP-4300 장비가 RS-232를 통해 개인용 컴퓨터와 연결되어 시뮬레이션과 실측 데이터를 비교분석 할 수 있게 하였다. 케이블의 영상분 임피던스 등 미진한 입력자료는 수정된 T&D와 BICC를 이용하였고, IEEE표준 데이터가 변압기 입력자료 측정에 적용되었다. 제안된 시스템은 대규모 실제 산업용 수변전 계통에 적용한 결과 고조파 진단의 유연성과 효율성을 입증할수 있었다.