초록
This study was performed to evaluate an applicability of the SMMCMAS system for reuse of the sewage from spa area and was operated to HLR(Hydraulic loading rate) of 211.3 to 126.8 $\ell$/㎥/d. The operating HRT(Hydraulic retention time) ranges were 2.5 to 1.5 hours. Conclusions are as follows; At the optimum HLR of 158.5 $\ell/\m^2$/d (HRT of 2.0 hours), the maximum BOD removal efficiency was 94% and the effluent BOD concentration was 1.1mg/$\ell$ in result. As the HLR was increased to 211.3 $\ell/\m^2$/d, BOD removal efficiency was decreased to 75% and BOD removal efficiency was also reduced to 74% at lower HLR of 126.8 $\ell/\m^2$/d. It shows that the maximum BOD removal efficiency occurs at an optimum HLR value and that the removal efficiency decreases when the HLR is either higher or lower than the optimum value. Sludge production rates were ranged 0.01 to 0.24gVSS/gBODrem/d and accomplished to 0.01gVSS/gBODrem/d at the optimum HLR of 158.5 $\ell/\m^2$/d.