Abstract
The seismic design regulations have not been applied to the low-rised buildings which are less than 6 stories in Korea. For these buildings which are designed only for gravity loads, theoretical formulas which can estimate the seismic strength of building are derived. The column hinge sway and beam hinge sway mechanism are assumed for the formulars. For the comparisons with the formulas, the results of push-over analyses of 3 and 4 storied buildings are used. It can be shown that the estimating formulas correspond well with the push-over analyses. And the seismic strength of building has a little relations with the number of bay and becomes larger as the building becomes lower. Also, as the ratio and strength of reinforcing steel increase, the seismic strength of building is increased.
중력하중에 대하여서만 설계되고 내진에 대하여 설계되지 않은 6층 미만의 RC 골조를 대상으로 내진 저항력에 대한 추정식을 유도하였다. 추정식의 산정을 위하여 기둥 소성 힌지 붕괴기구와 보 소성 힌지 붕괴기구의 2가지 경우를 가정하여 이론식을 유도하였으며, 이를 4층 및 3층 건물의 push-over해석과 비교하였다. 연구 결과로, 중력 하중에 대하여서만 설계된 구조물의 내진 저항력은 bay수의 증가와 크게 관계가 없으며 저층일수록 증가하는 기존의 연구 결과와 잘 일치함을 알 수 있었다. 설계시 기둥의 철근 강도와 철근비가 증가할수록 내진 저항력이 증가함을 알 수 있었다. 또한 스팬의 길이보다는 기둥 춤의 크기가 내진저항력에 더 많은 영향을 미침을 알 수 있었다.