References
- P. M. Frank, 'Fault diagnosis in dynamic systems using analytical and Knowledge-based reduandancy: a survey and some results', Automatica, Vol. 26, No. 3, 459-474, 1990 https://doi.org/10.1016/0005-1098(90)90018-D
- Janos J. Gertler, 'Survey of Model-Based Failure Detection and Isolation in Complex Plants', IEEE Control Systems Magazine, December 1988 https://doi.org/10.1109/37.9163
- E. Y. Chow, A. S. Willsky, 'Analytical redundancy and the design of robust failure detection system', IEEE Trans. Autmat. Contr, Vol. AC-29, No. 7, July 1984 https://doi.org/10.1109/TAC.1984.1103593
- 김재화, 서열규, 장태규, 'Oscilatory 파형감지에 의한 보일러 플랜트 드럼 수위 제어계통의 고장 진단', 대한 전기학회 논문지 A권, 1999년 1월호
- K. J. Astrom, 'Simple drum-boiler model', IFAC Symposium Power System, Modeling and Control Applications, september 1988
- J. P. McDonald, H. G. Kwatny, J. H. Spare, 'A nonlinear model for reheat boiler-tubine-generator systems, Parts I', Proc. 12th JACC, 1971, pp. 219-236
- J. P. McDonald, H. G. Kwatny, and J. H. Spare, 'A nonlinear model for reheat boiler-tubine-generator systems, Parts II', Proc. 12th JACC, 1971, pp. 219-236
- F. P. de Mello, 'Boiler models for system dynamic performance studies', IEEE Trans. Power Systems, Vol. 6, No. 1, Feb 1991 https://doi.org/10.1109/59.131048
- M. E. Flynn, M. J. O'Malley, 'Drum Boiler Model for Long Term Power System Dynamic Simulation', IEEE Trans Power Systems, Vol.14, No. 1 Feb 1999 pp 209-217 https://doi.org/10.1109/59.744528
- 보령화력 1,2호기 기본운전지침서, 한국전력공사
- Bailey Instruction Book, Bailey 820 analog control system description for KEPCO