Abstract
Foamed concrete for cast-in-site, which shows excellent lightweight, thermal insulation, noise insulation, constructability and cost efficiency, has been applied as thermal insulation or filling material for On-dol. However, the technology is too insufficient to obtain the high level of quality, and serious problems often occur in quality control at sites. It, thus, is necessary to establish the proper and reasonable quality control method for ensuring the required quality, based on the investigation on the physical properties and their reciprocal relation. This study aims to settle the quality control method in case of applying FA foamed concrete replacing 40% by weight with fly-ash as the filling material for On-dol. The results of the study include the correlation among flow, as-placed density and foam ratio of fresh foamed concrete, the correlation between physical properties before hardening and after 28-day, provision of an equation to estimate 28-day compressive strength early with 7-day compressive strength, and suggestion of quality criteria for the revision of KS on foamed concrete for cast-in-site.
현장타설 경량기포콘크리트는 경량성, 단열성, 흡음성, 시공성, 경제성 등이 우수하여 온돌바닥의 단열용 또는 채움용으로 사용되고 있다. 그러나, 경량기포콘크리트의 품질확보를 위한 세부기술개발이 미흡하여, 현장에서의 품질관리방법을 정립할 필요가 있으며, 이를 위하여 경량기포콘크리트의 물리적 성질 및 상호관계에 대한 구명이 요구된다. 본 연구는 시멘트 중량의 40%를 플라이애시로 치환한 FA기포콘크리트를 온돌 채움용으로 사용할 경우의 품질관리 방안을 확립하기 위한 것으로서, 굳지 않은 경량기포콘크리트의 플로우, 기포슬러리 비중, 기포율 간의 상호관계 및 경화전 물성과 경화후 물성(겉보기 비중, 28일 압축강도) 간의 상호관계를 구명하였으며, 7일 압축강도를 이용하여 28일 압축강도를 조기에 추정하기 위한 관계식을 제시하고, 또한 현장타설용 기포콘크리트에 대한 KS 규격 개선안을 제시하였다.