DOI QR코드

DOI QR Code

Hand Exoskeleton with PWM Driving Method

초음파 모터 구동방식의 역감제시 기구

  • Published : 2001.06.01

Abstract

In this paper, we present an exoskeletal haptic device named SKK Hand Master. This device is directly driven linkages actuated with small ultrasonic motors. By adopting ultrasonic motors that have advantageous features useful for cybernetic actuators, a compact haptic device containing whole driving packages can be established without additional power transmissions such as tendons. Methods for measuring joint postures and joint torques are developed and a new control strategy called PWM/PS is proposed to overcome intrinsic disadvantages such as hysteresis. Issues regarding design and construction of the device are addressed and several results of experiments for the evaluations of performance are included.

Keywords

References

  1. Hill, J. R., Green, P. S., Jensen, J. F., Gorfu, Y. and Shah, A. S., 1994, 'Telepresense Surgery Demonstration System,' in Proc. of IEEE International Conference on Robots and Automation, pp. 2302-2307 https://doi.org/10.1109/ROBOT.1994.350942
  2. Hunter, I. W., Doukoglou, T. D., Lafontaine, S. R., Charette, P. G., Jones, L. A., Sagar, M. A., Mallinson, G. D. and Hunter, P. J., 1993, 'Teleoperated Microsurgical Robot and Associated Virtual Environment for Eye Surgery,' Presence, Vol. 2, No.4, pp. 265-280
  3. Rohling, R. N. and Hollerbach, J. M., 1994, 'Modeling and Parameter Estimation of the Human index Finger,' in IEEE International Conference on Robotics and Automations, pp. 223-230 https://doi.org/10.1109/ROBOT.1994.350984
  4. Satava, R. M., 1998, Cybersurgery, John Wiley & Sons Inc., New York
  5. Burdea, G., 1996, Force and Touch Feedback for Vir- tual Reality, John Wiley & Sons Inc., New York
  6. Buttolo, P. and Hannaford, B., 1995, 'Pen-Based Force Display for Precision Manipulation in Virtual Environments,' in IEEE Virtual Reality Annual International Symposium, pp. 217-224 https://doi.org/10.1109/VRAIS.1995.512499
  7. Massie, T. and Salisbury, K., 1994, 'The Phantom Haptic Iinterface: A Device for Probing Virtual Objects,' in ASME Winter Annual Meeting, pp. 295-300
  8. Bergamasco, M., 1996, 'Force Replication to the Human Operator: The Development of Arm and Hand Exoskeletons as Haptic Interfaces,' in Robotics Re- search : The Seventh International Symposium, Springer-Verlag London Ltd., pp. 173-182
  9. Iwata, H., Nakagawa, T. and Nakashima, T., 1992, 'Force Display for Presentation of Rigidity of Virtual Objects,' Journal of Robotics and Mechatronics, Vol. 24, No. 1, pp. 39-42
  10. Bouzit, M., Richard, P. and Coiffe, P., 1993, 'The LRP Dextrous Hand Master Control System,' Technical Report, Laboatoire de Robotique de Paris
  11. Bouzit, M., Burdea, G. and Coiffet, P., 1993, 'The LRP Dextrous Hand Master,' in Virtual Reality Systems Fall '93, NY
  12. Burdea, G., Zhuang, J., Roskos, E., Silver, D. and Langrana, N., 1992, 'A Portable Dextrous Master with Force Feedback,' Presence-Teleoperators and Virtual Environments, Vol. 1, No.1, pp. 18-27
  13. Tomovic, R. and McGhee, R. B., 1966, 'A Finite State Approach to the Synthesis of Bio-engineering Control Systems,' IEEE Trans. on Human Factor in Electronics, Vol. 7, No.2, pp. 65-69 https://doi.org/10.1109/THFE.1966.232325
  14. Sashida T. and Kenjo, T., 1993, An Introduction to Ultrasonic Motors, Oxford Science Publications
  15. Hagood IV, N. W. and McFarland, A. J., 1995, 'Modeling of a Piezoelectric Rotary Ultrasonic Motor,' IEEE Trans. on Ultrasonics, Ferroelectrics, and Frequency Control, Vol. 42, No.1, pp. 210-224 https://doi.org/10.1109/58.365235
  16. Kaneko, M., Nishihara, T. and Tsuji, T., 1995, 'Active Control of Self-Locking Characteristic of Ultrasonic Motor,' in Proc. IEEE International Conference on Robotics and Automation, pp. 2928-2934 https://doi.org/10.1109/ROBOT.1995.525699
  17. Noma, H., Miyasato, T., Kitamura, Y. and Kishino, F., 1996, 'Haptic and Visual Feedback for Manipulation Aid in a Virtual Environment,' ASME Journal of Dynamic Systems, Measurement and Control, Vol. 58, pp. 469-476
  18. Choi, B. H. and Choi, H. R., 1999, 'A Semi-Direct Drive Hand Exoskeleton Haptic Device Using Ultrasonic Motors,' in ROMAN '99, pp. 205-209 https://doi.org/10.1109/ROMAN.1999.900354
  19. 대한해부학회 용어사전, http://anatomy.or.kr, 1997