DOI QR코드

DOI QR Code

Effects of Tube Diameter on Nucleate Pool Boiling Heat Transfer

튜브 직경이 풀핵비등 열전달에 미치는 영향

  • 강명기 (안동대학교 기계공학교육과)
  • Published : 2000.07.01

Abstract

A series of data sets for the heat transfer coefficient versus wall superheat has been obtained experimentally using various combinations of tube diameters ($9.7{\sim}25.5mm$), surface roughness ($15.1{\sim}60.9nm$), and tube orientations (horizontal and vertical) to obtain effects of tube diameters on nucleate pool boiling heat transfer for the saturated water at atmospheric pressure. In addition, the results are compared with the well known Cornwell and Houston's correlation for horizontal tubes to identify the deviation of the present experimental data from the correlation and the applicability of it to vertical tubes. The experimental results show that the heat transfer coefficient decreases as the tube diameter increases for both horizontal and vertical tubes and they are in good agreement with the Cornwell and Houston's correlation within ${\pm}20%$ scatter range.

Keywords

References

  1. Corletti M. M. and Hochreiter L. E., 1991, 'Advanced Light Water Reactor Passive Residual Heat Removal Heat Exchanger Test,' Proc. of the 1st JSME/ASME Joint International Conference on Nuclear Engineering, Tokyo, Japan, pp. 381-387
  2. Kang M. G., 1998, 'Experimental Investigation of Tube Length Effect On Nucleate Pool Boiling Heat Transfer,' Annals of Nuclear Energy, Vol. 25, No. 4-5, pp. 295-304 https://doi.org/10.1016/S0306-4549(97)00056-X
  3. Chun M. H. and Kang M. G., 1998, 'Effects of Heat Exchanger Tube Parameters on Nucleate Pool Boiling Heat Transfer,' Trans. ASME, J. of Heat Transfer, Vol. 120, pp. 468-476
  4. Cornwell K., Schuller R. B., and Einarsson J. G., 1982, 'The Influence of Diameter on Nucleate Boiling Outside Tubes,' Proceedings of The Seventh International Heat Transfer Conference, Munchen, Germany, Vol. 4, pp. 47-53-
  5. Chongrungreong S. and Sauer, Jr. H. J., 1980, 'Nucleate Boiling Performance of Refrigerants and Refrigerant-Oil Mixtures,' Trans. ASME, J. of Heat Transfer, Vol. 102, pp. 701-705
  6. Cornwell K. and Houston S. D., 1994, 'Nucleate Pool Boiling on Horizontal Tubes: a Convection-Based Correlation,' Int. J. Heat Mass Transfer, Vol. 37, Suppl. 1, pp. 303-309 https://doi.org/10.1016/0017-9310(94)90031-0
  7. van Stralen S. J. D. and W. M. Sluyter, 1969, 'Investigations on the Critical Heat Flux of Pure Liquids and Mixtures under Various Conditions,' Int. J. Heat Mass Transfer, Vol. 12, pp. 1353-1384 https://doi.org/10.1016/0017-9310(69)90022-2
  8. Hahne E. and Feurstein G., 1977, 'Heat Transfer in Pool Boiling in the Thermodynamic Critical Region: Effect of Pressure and Geometry,' In Heat Transfer in Boiling (Edited by Hahne E. and Grigull U.), Chap. 8, pp. 159-206
  9. 강명기, 2000, '튜브설치방향이 풀비등열전달에 미치는 영향,' 대한기계학회논문집 B권, 제24권 제1호, pp. 143-151
  10. Gupta A., Saini J. S., and Varma H. K., 1995, 'Boiling Heat Transfer in Small Horizontal Tube Bundles at Low Cross-Flow Velocities,' Int. J. Heat Mass Transfer, Vol. 38, No. 4, pp. 599-605 https://doi.org/10.1016/0017-9310(94)00282-Z