실리콘 기판 위에서 구현된 회전형 전기영동분리기

Cyclic Capilary Electrophoresis Separator on Silicon Substrate with Synchronized Switching

  • 정용원 (서울대 공대 전기공학부) ;
  • 김봉환 (서울대 공대 전기공학부) ;
  • 이준엽 (서울대 공대 전기공학부) ;
  • 조경연 (서울대 공대 전기공학부) ;
  • 장준근 (서울대 공대 전기공학부) ;
  • 전국진 (서울대 공대 전기공학부)
  • 발행 : 2000.11.01

초록

We have developed a synchronously switched cyclic capillary electrophoresis (CE) separator that is fabricated on a silicon substrate and glass containing reservoirs, Au electrode, and isolated channels. The advantage of a cyclic separator is the high resolution and ability to separate each sample to the designated reservoir from mixed samples. This approach makes it possible to reduce the supplied voltage and the total size. Another goal of this work is to introduce the methodolgy of electroosmosis flow(EOF) to silicon substrate and to separate DNA samples using a modified double-T injector.

키워드

참고문헌

  1. Effenhauser, C.S., A. Paulus, A.Manz, and M.H.Widmer, High speed separation if antisense oligonucleotides on a Micromachined capillary electrophoresis device Analysis chemistry, 1994, 66, pp2949-2953
  2. P.Renaud, H.Lintel, M.Heuschkel and L.Guerin, 'Photo-polymer microchannel technologies and applications', 1998, Proceeding of UTAS, Canada, pp17-22
  3. F.Heeren, E.Verpoorte, A.Mantz, and W.Thormann, Miscellar electrokinetic chromatography separations and analyses of biological samples on a cyclic planar microstructure, Analysis chemistry, 1996, 68, pp. 2044-2053
  4. St claire R L 1996 Anal. Chem. 68 569R-86R https://doi.org/10.1021/a1960018a
  5. H. becker et al, planar quartz chips with submicron channels for two dimensional capillary electrophoresis applications, J. micromech. microeng. 8, 1998, pp24-28 https://doi.org/10.1088/0960-1317/8/1/004
  6. A. Mantz C.S. effenhauser et al, electroosmotic pumping and electrophoretic separations for miniaturized chemical analysis systems, J. micromech. micoeng. 1994, pp257-265 https://doi.org/10.1088/0960-1317/4/4/010
  7. A.Mantz et al., u-tas : miniaturized total analysis systems, u-TAS conference, 1996, pp5-27
  8. 권현정, 장용근 DNA chip technology, 1997, 생물화공 제11권 3호, pp18-25
  9. L.shultz-lockyear et al Effects of injector geometry and sample matrix on injection and sample loading in integrated capillary electrophoresis devices, Electrophoresis, 1999, 20, pp529-538
  10. J.R.Webster and C.H.Mastrangelo, Large-volume integrated capillary electrophoresis stage fabricated using micromachining of plastics on silicon sub , Transducer97, 1997, pp503-506 https://doi.org/10.1109/SENSOR.1997.613697
  11. R.B.M. Schasfort, J.Hendrikse, and A.Berg, ${\mu}$ transparent insulating channels as components for miniaturized chemical separation devices , Proceeding of transducer 99, 1999, pp872-875
  12. P.Camilleri Capillary electrophoresis : theory and practice 2nd edition, CRC Press, 1998, pp102-105
  13. P.G.Righetti Capillary electrophoresis in analytical biotechnology, CRC Press, 1996, pp3-5