This paper presents an extended integral control with the PI controller by introducing the delay and decaying factors. The extended integral control scheme is developed by substituting the proportional convolution integral control for the PI(Proportional Integral) control. So far, the integral part of PI controller produces a signal that is proportional to the time integral of the input signal to the controller. The steady-state operation points are affected forever by errors in the past due to the input signal containing the information of the error in the past. These phenomena may cause some disturbances for other control purposes related to the given PI control. Introduction of forgetting factors to the error in the past can resolve the disturbance problems. Various forgetting factors are developed using the delay elements, the decaying factors, and the combination of the delay and decaying factors. The proposed various extended integral control schemes can be applicable to the corresponding PI control designs in which the error in the past may badly affect the current steady-state operation points and may cause some disturbances for other control purposes.