This paper presents an extended integral control with the PI controller by introducing the delay and decaying factors. The extended integral control scheme is developed by substituting the proportional convolution integral control for the PI(Proportional Integral) control. So far, the integral part of PI controller produces a signal that is proportional to the time integral of the input signal to the controller. The steady-state operation points are affected forever by errors in the past due to the input signal containing the information of the error in the past. These phenomena may cause some disturbances for other control purposes related to the given PI control. Introduction of forgetting factors to the error in the past can resolve the disturbance problems. Various forgetting factors are developed using the delay elements, the decaying factors, and the combination of the delay and decaying factors. The proposed various extended integral control schemes can be applicable to the corresponding PI control designs in which the error in the past may badly affect the current steady-state operation points and may cause some disturbances for other control purposes.

Keywords

References

  1. Chi-Tsung Huang, Chin-Jui Chou and Li-Zen Chen, 'An Automatic PID Controller Tuning Method by Frequency Response Techniques', The Canadian journal of chemical engineering, Vol.75, pp.596-603, Jun. 1997
  2. Yongho Lee, Sunwon Park, Moonyoung Lee, and Coleman Brosilow, 'PID Controller Tuning for Desired Closed-Loop Responses for SI/SO Systems',AIChE Journal, Vol.44, No.1, pp.106-115, Jan. 1998 https://doi.org/10.1002/aic.690440112
  3. Su Whan Sung, In-Beum Lee and Jitae Lee, ' Modified Proportional-Integral Derivative(PID) Controller and a New Tuning Method for the PID Controller', Ind. Eng. Chem. Res., pp.4127-4132, 1995 https://doi.org/10.1021/ie00038a058
  4. Y.-H.Moon, H.-S. Ryu, B.-K. Choi, and H.-J. Kook, 'Improvement of System Damping by Using the Differential Feedback in the Load Frequency Control', Proc. of the IEEE WM'99, Vol.1, pp.663-688., Feb. 1999
  5. Y.-H.Moon, H.-S. Ryu, B.-K. Choi, and B.-H. Cho, 'Modified PID Load-Frequency Control with the Consideration of Valve Position Limit', Proc. of the IEEE WM'99, Vol.1, pp.701-706, Feb. 1999
  6. Weng-Khuen Ho, Chang-Chien Hang, and Lisheng S., 'Tuning of PID Controllers Based on Gain and Phase Margin Specifications', Automatica, Vol.31, No.3, pp.497-502, 1995 https://doi.org/10.1016/0005-1098(94)00130-B
  7. E. Poulin and A. Pomerleau, 'Unified PID design method based on a maximum peak resonance specification', IEE Proc. Control Theory Appl., Vol.144, No.6, pp.566-574, Nov. 1997 https://doi.org/10.1049/ip-cta:19971493
  8. Tor Steinar, 'Automatic Tuning of PID Controllers Based on Transfer Function Estimation', Automatica, Vol.30, No.12, pp.1983-1989, 1994 https://doi.org/10.1016/0005-1098(94)90060-4
  9. IEEE Committee Report, 'Dynamic Models for Steam and Hydro Turbines in Power System Studies', IEEE Trans. on Power Apparatus and Systems, Vol.PAS-92, No.6, Nov. 1973, pp.1904-1915 https://doi.org/10.1109/TPAS.1973.293570