Analytical Modeling of Seismic Steel Moment Connections Reinforced with Welded Straight Haunch

용접 수평헌치로 보강된 내진 철골 모멘트 접합부의 해석적 모형화

  • 이철호 (경남대학교 공간환경시스템 공학부) ;
  • 윤태호 (창원대학교 건축공학과)
  • Received : 2000.07.27
  • Published : 2000.10.27

Abstract

This paper describes new analytical modeling for steel moment connections with welded straight haunch. Among a variety of new details for seismic steel moment connections proposed after the 1994 Northridge and the 1995 Hyogo-Ken Nanbu earthquake, one viable solution was to strengthen the connection by adding a triangular haunch on the bottom side of the beam. However, a simpler design has been called for because of the increased labor associated with fitting the triangular haunch. Adding a straight haunch is one alternative. But a mathematical model that forms the design basis is not available. A simplified analytical model that considers the force interaction and deformation compatibility between the beam and haunch is developed in this study. The proposed modeling predicted quite reasonably the interaction forces at the beam-haunch interface and the flexural stresses in the beam and haunch flange groove welds.

본 논문에서는 용접 수평헌치로 보강된 내진 철골모멘트접합부를 간단히 해석적으로 모형화하는 새로운 방안을 제시하였다. 1994년 노스리지 및 1995년 효고현 남부 지진피해 이후 철골모멘트접합부의 새로운 내진상세가 다양하게 제시되어 왔다. 이 가운데 보의 하부를 헌치로서 보강하는 방안도 유망한 대안의 하나로 평가되고 있다. 삼각헌치 대신 수평헌치를 도입하면 보강작업이 용이하고 경제적으로도 유리하나 아직 응력전달 메카니즘이 규명되지 않고 있어서 정립된 설계방안이 존재하지 않는다. 본 연구에서는 보와 헌치의 상호작용 및 변형의 적합조건을 고려하여 이 문제의 해결방안을 제시하였다. 본 연구의 방안에 의해 설계에 필요한 보-헌치의 상호작용력 및 보와 헌치 플랜지 용접부의 휨응력도를 만족스럽게 예측할 수 있다.

Keywords

Acknowledgement

Supported by : 학술진흥재단

References

  1. Journal of Structural Engineering, ASCE v.123 no.1 Analytical modeling of dual panel zone In haunch repaired steel MRFs Lee, C.H.;Uang, C.M.
  2. Journal of Structural Engineering, ASCE v.126 no.1 Cyclic testing of steel moment connections rehabilitated with RBS or welded haunch Uang, C.M.;Yu, Q.S.;Noel, S.;Gross, J.
  3. Journal of Structural Engineering, ASCE v.126 no.1 Seismic rehabilitation design of steel moment connection with welded haunch Yu, Q.S.;Uang, C.M.;Gross, J.
  4. Modification of existing welded steel moment frame connections for seismic resistance;Steel Design Guide Series 12 Gross, J.L.;Engelhardt, M.D.;Uang, C.M.;Kasai, K.;Iwankiw, N.R.
  5. Static cyclic testing of pre-Northridge and haunch repaired steel moment connections, SAC 96-01 Uang, C.M.;Bondad, D.
  6. ABAQUS users manual. Vols. I and II
  7. SAP2000 analysis reference Vol. I
  8. Testing of repair concepts for damaged steel moment connections, SAC 96-01 Shuey. B.D.;Engelhardt. M.D.;Sabol. T.A.