Changes of lateral cephalometric values according to the rotation of head

두부회전에 따른 측모두부방사선 계측치의 변화

  • Kim, Kwang-Soo (Department College of Dentistry, Chosun University) ;
  • Hwang, Mee-Sun (Department of Orthodontics, College of Dentistry, Chosun University) ;
  • Choi, Eui-Hwan (Department of Oral & Maxillofacial Radiology, College of Dentistry, Chosun University) ;
  • Kim, Kwang-Won (Department of Orthodontics, College of Dentistry, Chosun University) ;
  • Yoon, Young-Jooh (Department of Orthodontics, College of Dentistry, Chosun University)
  • 김광수 (조선대학교 대학원 치의학과) ;
  • 황미선 (조선대학교 치과대학 교정학교실) ;
  • 최의환 (조선대학교 치과대학 구강악안면 방사선학교실) ;
  • 김광원 (조선대학교 치과대학 교정학교실) ;
  • 윤영주 (조선대학교 치과대학 교정학교실)
  • Published : 2000.02.01

Abstract

This study was performed to find out the effect of projection errors on cephalometric linear and angular measurements according to head rotation during taking lateral cephalometric radiographs. Seventeen skulls with permanent dentition and no gross asymmetry were obtained from the Department of Anatomy, Medical School, Chosun University. Total 527 x-ray films were taken with $1^{\circ}$ interval from the reference position($0^{\circ}$) to ${\pm}15^{\circ}$ around the vertical axis (Z axis) which is perpendicular to the midpoint of the line connecting the center of two ear rods in submento-vertex direction. Statistical analysis was performed by paired t-test if there were statistically significant differences between the mean of the reference position($0^{\circ}$) and that of each rotation angle. The following results were obtained. 1. The projection errors of angular measurements were smaller than those of linear measurements. 2. The projection errors of angular measurements including midline landmarks were smaller than those including bilateral landmarks. 3. The horizontal linear measurements were gradually decreased when the stroll was rotated toward the film, but slightly increased and then decreased when the skull was rotated toward the focal spot. However, the changes were smaller in focal direction. 4. The projection errors of horizontal linear measurements were larger than those of vertical linear measurements. 5. The projection errors of vertical linear measurements were increased with increased distance from the rotation axis to vertical measurements. It is concluded that the use of angular measurements rather than linear measurements is recommended to minimize the projection errors.

본 연구는 측모두부방사선사진 촬영시 발생될 수 있는 두부회전이 측정된 선, 각계측치들에 어느 정도의 투사오차를 야기시키는지 알아보기 위해 조선대학교 의과대학 해부학교실에 소장중인 건조두개골 중 비교적 상태가 양호하고 특별한 비대칭이 없는 영구치열기의 건조두개골 17개를 표본으로 선택하여 시행하였다. 각각의 건조두개골을 수직축(Z축)을 중심으로 기준위치($0^{\circ}$)에 대해 $1^{\circ}$ 간격으로 ${\pm}15^{\circ}$ 까지 실험적으로 회전시켜 총 527장의 측모두부방사선사진을 촬영하였다. 이를 근거로 기준위치($0^{\circ}$)에서의 계측치와 각 회전각에서의 계측치들 사이에 paired t-test를 시행하여 측모두부방사선사진 계측치간의 차이를 규명하였으며, 이를 통해 추사오차의 관점에서 교정학적으로 유용한 측모두부방사선 계측항목을 구한 결과 다음과 같은 결론을 얻었다. 1. 각계측항목이 선계측항목에 비해 투사오차가 작았다. 2. 각계측항목은 정중시상면에 위치한 기준점들을 많이 포함할수촉 투사오차가 작았다. 3. 수평 선계측항목의 길이는 필름방향으로 회전됨에 따라 점진적으로 감소되었으나, 초점 방향으로 회전됨에 따라서는 증가되다가 감소되었으며 상대적으로 그 변화양이 작았다. 4. 두부회전에 따른 투사오차는 수직선계측항목에 비해 수평선계측항목에서 컸다. 5. 수직선계측항목은 회전축으로부터 거리가 증가함에 따라 투사오차가 증가하였다. 이상을 종합해 볼 때 두부회전에 따른 측모두부방사선사진 계측치의 투사오차를 최소로 하기 위해서는 선계측항목보다는 각계측항목을 사용하는 것이 유용할 것으로 사료된다.

Keywords