Development of Intravascular Micro Active Endoscope(I) -Analysis of Lubrication Characteristics of Small Arteries with Micro Catheter Insertion-

혈관 삽입형 초소형 작동형 내시경의 개발(I) - 도뇨관 삽입시 혈관 내부의 윤활 특성 분석 -

  • 장준근 (서울대학교 정밀기계설계공동연구소) ;
  • 김중경 (서울대학교 대학원 협동과정 의용생체공학전공)
  • Published : 1999.09.01

Abstract

The objective of this investigation is to examine the influence of the micro catheters, which mimic the intravascular micro active endoscopes, on local pressure changes and flow rate in an arterial branch model similar to the femoral artery of human. The effects of branch to main lumen flow rate ratios and the locations of a catheter tip were found to be significant on the local pressure changes. Relatively large pressure drops and an increase in shear stress due to the obstruction effects may induce an endothelial cell damage and a change in arterial wall permeability, which have been reported to be the primary cause of the initiation of the atherosclerosis and other major vascular diseases.

Keywords

References

  1. Circulation v.73 no.6 Measurement of Transstenotic Pressure Gradient During Percutaneous Transluminal Coronary Angioplasty Anderson, H. V.;Roubin, G. S.;Leimgruber, P. P.;Cox, W. R.;Douglas, J. S.;King Ⅲ, S. B.;Gruentzig, A. R.1.;Anderson, H. V.
  2. Circulation v.76 no.4 The Transstenotic Pressure Gradient Trend as a Predictor of Acute Complications After Percutaneous Transluminal Coronary Angioplasty Redd, D. C. B.;Roubin, G. S.;Leimgruber, P. P.;Abi-Mansour, P.;Douglas, J. S.;King Ⅲ, S. B.
  3. Med. Phys. v.17 no.5 Some Possible Effects of a Catheter on the Arterial Wall Karahalios, C. B.
  4. J. Biomech. Eng. v.107 no.3 Experimental Investigation of Branch Flow Ratio, Angle, and Reynolds Number Effects on the Pressure and Flow Fields in Arterial Branch Models Cho, Y. I.;Back, L. H.;Crawford, D. W.
  5. J. Biomech. Eng. v.107 no.3 Pressure Difference Flow Rate Variation in a Femoral Artery Branch Casting of Man for Steady Flow Cho, Y. I.;Back, L. H.;Crawford, D. W.
  6. J. Biomech. v.16 no.11 Experimental Study of Pulsatile and Steady Flow Through a Smooth Tube and an Atherosclerotic Coronary Artery Casting of Man Cho, Y. I.;Back, L. H.;Crawford, D. W.;Cuffel, R. F.
  7. J. Biomech. Eng. v.109 no.1 Fluid Particle Motion and Lagrangian Velocities for Pulsatile Flow Through a Femoral Artery Branch Model Back, M. R.;Cho, Y. I.;Crawford, D. W.;Back, L. H.
  8. 대한기계학회논문집 v.18 no.10 뉴턴유체와 비뉴턴유체에 대한 분지관 유동의 수치해석 서상호;유상신;노형운
  9. J. Biomech. v.27 no.2 Estimated Mean Flow Resistance Increase During Coronary Artery Catheterization Back, L. H.
  10. J. Biomech. Eng. v.118 no.1 Flow Rate-Presure Drop Relation in Coronary Angioplasty : Catheter Obstruction Effect Back, L. H.;Kwack, E. Y.;Back, M. R.
  11. 윤활학회지 v.15 no.3 혈관 삽입용 초소형 작동형 내시경의 개발(Ⅱ)-시스템 설계, 제작 및 체외성능 분석 장준근; 정 석;이용구