In this study, the validity of the currently used seismic regulations for seismic isolated building structures is investigated, and a new formula for vertical distribution of seismic load is proposed. The distribution formula in UBC-91 did not provide sufficient safety, and thus revised in 1994. However it is pointed out that the revised formula overestimates the seismic load because of its similarity to that of the fixed-base structure. Therefore, in the proposed approach, it is intended to satisfy safety, economy, and applicability by combining the mode shapes of the seismic isolated structure idealized as two degrees of freedom system and those of fixed-base structure. For verification of the proposed formula, both a moment resisting frame and a shear wall system are analyzed. The results obtained from the proposed method turn out to be close to the results from a dynamic analysis.
본 논문에서는 일반적으로 사용되고 있느 면진건축물의 내진설계기준에 대한 타당성을 검증하고 새로운 층지진하중 산정식을 제안하였다 UBC-91의 층지진하중 산정식은 충분한 안전성을 가지지 못하였으므로 94년에 개정이 되었다 그러나 개정된 산정식도 고정기초건축물과 유사한 층지진하중 산정식을 사용하였으므로 비경제성이 문제점으로 지적되고 있다 그러므로 제안된 식에서는 2자유도계 면진건축물과 고정기초건축물의 모드형상을 이용하여 안전성, 경제성 및 적용성을 만족시키도록 하였다. 제안된 층지진하중 산정식의 정확성 및 적용성을 검증하기 위하여 코멘트저항 골조형식과 전단변 구조형식의 구조물의 예제해석을 수행하였으며 동적해석의 경우와 근접한 결과를 얻었다.