Abstract
The newly designed Ac-PDP(plasma display panel with comb-type electrode) structure was fabricated by using the screen printing method and the electrical and optical characteristics were measured under the various discharge conditions. The minimum firing voltages measured under pure Ne and Ne+Xe mixture gas with the application of 10 kHz square wave were 190V and 160V, respectively. The firing voltages of the PDP cell with the comb-type electrode were compared with those of the cell with matrix electrode under the same discharge condition. The firing voltage of the PDP cell with comb-type electrode was 15 V lower than that of the PDP cell with conventional matrix electrodes.