Laser scanning unit with plastic f$\theta$ lenses featuring high resolution

600DPI용 플라스틱 f$\theta$렌즈가 실장된 Laser Scanning Unit 의 측정 및 평가

  • 임천석 (삼성전기(주) 종합연구소 광메카/광기기)
  • Published : 1999.10.01

Abstract

We investigate the evaluation items of LSU (Laser Scanning Unit), such as beam size, f$\theta$ characteristics, linearity, skew and bow, optical power ratio between image height of 0mm and $\pm$108 mm, pitch error, Jitter and shift of printing position. Through the measurement of LSU using BSH (Beam Scan Head) installed on LMC (Linear Motion Controller) which moves linearly within the whole scanning range (-108 mm~+108 mm), we can ascertain plastic f$\theta$ lenses, which are manufactured by TVLP (Two-step Variable Low Pressure) molding method, to satisfy 600DPI(Dots Per Inch) performance.

일반적으로 LSU(Laser Scanning Unit)는 LD모듈(Laser Diode, 콜리메이팅 렌즈, 슬릿), 실린더 렌즈 고속회전하는 PM(Polygon Mirror), f$\theta$렌즈와 같은 광부품들과 이들을 취부하는 Housing으로 구성되어져 있다. 먼저 본 논문에서는 당사에서 자체적으로 광설계된 LSU 시작품(시작(試作品)을 측정/평가하기 위해 평가항목들에 관해 살펴 보았다. 당사에서 시제작된 LSU의 특징은 LSU의 핵심부품인 f$\theta$렌즈가 2단가압형 저압사출방식으로 제작되었다는 것이다. LSU의 평가항목들은 BSH(Beam Scan Head)를 LMC(Linear Motion Controller)위에 장착해서 비교적 간단히 측정 할 수 있었고, 측정결과 600DPI(Dots Per Inch) 성능을 만족함을 확인할 수 있었다.

Keywords

References

  1. OPTRONICS v.10 西澤鉉一
  2. OPTRONICS v.4 中井武彦
  3. Proc. SPIE v.1670 T. Hisada;T. Maruyama;H. Inage;M. Deguchi;Y. Ariki
  4. 光技術 v.34 no.4 左康浩
  5. 光技術 v.36 no.10 小瀨古久秋
  6. J. Imaging Tech. v.15 W. Lama;S. Feth;R. Loce
  7. J. Appl. Photog. Engr. v.9 M. Maltz
  8. J. Imaging Tech. v.14 R. R. Frith;D. Kessler;E. Muka;K. Naor;J. C. O.wens
  9. J. Imaging Tech. v.12 Y. Miyake;S. Inoue;M. Inui;S. Kubo
  10. IEEE Trans. on Communication COM-29 J. C. Stoffel;J. F. Moreland